Bosch Appliances D9412GV2 manual A# Acct O/C, Area

Models: D9412GV2

1 158
Download 158 pages 17.38 Kb
Page 44
Image 44
A# Acct O/C

D9412GV2/D7412GV2 Program Entry Guide 2.0 GV2MAIN

EN 44

To suppress reports:

Use Opening/Closing Windows to suppress reports for a specified period of time and then automatically turn them on again.

Use the Restricted O/C options. A Closing Report is sent if the user is force arming, sending duress, or bypass arming. An Opening Report is sent if the user is disarming during an alarm condition or unbypasses points when disarming. If the system is normal, no Opening or Closing Report is sent.

For the scheduled suppression of Opening and Closing Reports, refer to Section 5.1.1 Opening and Closing) to define Opening and Closing Windows.

Account Opening and Closing Reports

Opening and Closing Reports are sent by account when the last area in a group of areas with the same account number(s) is armed.

Area Opening and Closing Reports

Closing Reports are sent for each area as it is armed. The account number is also sent for each area.

Customizing Account Opening and Closing Reports

You can eliminate area Opening and Closing Reports from selected areas in the account by programming A# Area O/C as No for those areas.

Combination Account and Area Opening and Closing Reports

To send both account openings and closings, and individual area openings and closings for all areas in the account, you must:

Program A# Acct O/C as Yes for all areas in the account.

Program A# Area O/C as Yes for all areas in the account.

Closing Reports: When areas in the account are independently armed, each area generates an Area Closing Report. When the last area is armed, it also generates an Account Closing Report.

Opening Reports: When the first area in the account is disarmed, it generates an Account Opening Report along with an Area Opening Report. When the remaining areas in the account are disarmed, each area generates an Area Opening Report.

Area Only Opening Closing Supervision Features

Use these features to supervise opening and closing activity by area. Auto Close, Fail To Open, and Fail To Close all work independently of the A# Acct O/C feature. To use these features, program O/C Windows.

Area

Default: 1

Selection: 1 to 8

Enter the area number you are programming.

A# Acct O/C

Default:

 

No

Selection:

 

Yes or No

Yes

 

Send Opening and Closing Reports

 

 

by account.

 

 

Use this selection if the control panel

 

 

sends reports to an automation

 

 

system that cannot interpret multiple

 

 

Area Opening and Closing Reports,

 

 

or if Modem Format is programmed

 

 

as No in the Phone category (BFSK

 

 

format is used and Opening and

 

 

Closing Reports are enabled).

 

 

An Account Opening Report is

 

 

generated when the first area in an

 

 

account is opened (disarmed). After

 

 

the Account Opening Report is sent,

 

 

disarming other areas in the account

 

 

does not generate another Account

 

 

Opening Report. An Account Closing

 

 

Report is generated only when the

 

 

last area in an account is closed

 

 

(armed). Opening and Closing

 

 

Reports for accounts do not contain

 

 

any area information.

 

 

Opening and Closing Windows

 

 

affect Account Opening and

 

 

Closing Reports: If an account

 

 

opening or closing is generated while

 

 

an Opening or Closing Window for

 

 

this area is in effect, and Disable O/C

 

 

in Window is programmed Yes, the

 

 

report is not sent. Use the same

 

 

opening and closing window times for

 

 

all areas sharing the same account

 

 

number.

No

 

Do not send Opening and Closing

 

 

Reports by account.

 

 

 

Determines if this area generates Account Opening and Closing Reports. Program this item the same for all areas in the account.