Bosch Appliances D9412GV2 manual SIA CP-01Quick Reference, Prompt Name, Bosch Recommended Settings

Models: D9412GV2

1 158
Download 158 pages 17.38 Kb
Page 150
Image 150
8.0 SIA CP-01 Quick Reference

D9412GV2/D7412GV2 Program Entry Guide 8.0 SIA CP-01 Quick Reference

EN 150

8.0 SIA CP-01 Quick Reference

Table 45: Programming the Control Panels for SIA CP--01 Compliance

 

 

 

 

Prompt Name

Bosch Recommended Settings

Shipping Default

References

 

for SIA CP-01 Compliance

 

 

Phone #

(Prefix backup phone number with

{Blank}

Page 11

 

Call Waiting disable command)

 

 

Duress Type

Option 3

0 (disabled)

Page 35

Cancel Report

Yes

Yes

Page 36

A# Exit Dly Time

45 sec to 255 sec

60 sec

Page 38

A# Duress Enable

Yes

No

Page 39

A# Exit Restart

Yes or No

Yes

Page 49

A# Arm No Exit

Yes or No

Yes

Page 49

A# Two Man Rule

No

No

Page 47

A# Early Ambush

No

No

Page 48

A# Exit Warning

Yes

Yes

Page 49

A# Entry Warning

Yes

Yes

Page 50

A# Burg Time1

6 min to 90 min

6 min

Page 42

A# Alarm Bell

1 to 128(64), A, B, C

A (on-board alarm output)

Page 79

CC# Entry Tone

Yes or No

Yes

Page 54

CC# Exit Tone

Yes or No

Yes

Page 54

CC# Abort Display

Yes or No

Yes

Page 56

CC# Cancel Display

Yes or No

Yes

Page 56

Master Arm Inst

{Blank}

{Blank}

Page 61

Perim Instant

{Blank}

{Blank}

Page 61

L## Send Duress

[Blank] or E

E2

Page 75

L## Disarm

[Blank] or E

E2

Page 67

L## Passcode Disarm

[Blank] or E

E2

Page 75

P## Entry Delay

30 sec to 240 sec

30 sec

Page 94

P## Alarm Abort

Yes or No

Yes3

Page 102

Abort Window

15 sec to 45 sec

30 sec

Page 140

Passcode Length

3 to 6 digits

Disabled

Page 141

Swinger Count

1 to 2 trips

1 trip

Page 141

Remote Warning

Yes

Yes

Page 141

Cross Point Time

5 to 255 sec

20 sec

Page 143

P## Cross Point

Yes or No

No

Page 100

1The SIA allowed range is 1 min to 90 min.

2L14 is the default duress user index.

3The default for P## Alarm Abort is No for P3, P4, P5, and P22.

Bosch Security Systems, Inc. 10/08 F01U003636-04

Page 150
Image 150
Bosch Appliances D9412GV2 SIA CP-01Quick Reference, Prompt Name, Bosch Recommended Settings, Shipping Default, References