D9412GV2/D7412GV2 Program Entry Guide 6.0 GV2AUX

EN 129

Call Back Enabled

Default:

No

Selection:

Yes or No

Yes

When the control panel hears the

 

correct RPS password (refer to RPS

 

Passcode in Section 2.7 RPS

 

Parameters on page 32), it ends the

 

SDI RPS session and then

 

reconnects to RPS using the RPS IP

 

Address if Enable Ext Modem is set

 

to No.

 

If Enable Ext Modem is set to Yes,

 

the control panel re-establishes

 

communication with RPS using the

 

RPS Dial String. This ensures that

 

the control panel communicates only

 

with valid RPS units.

 

 

No

The SDI RPS session starts

 

immediately; no call-back is

 

required. The control panel can

 

engage in SDI RPS sessions

 

regardless of the originating location.

 

 

Using this function allows the control panel, after verifying the RPS pass code, to provide an additional level of security. Before allowing any upload or download, it ends the SDI RPS session and then reconnects with RPS using one of the following:

The RPS IP Address (Enable Ext Modem must be set to No)

The RPS Dial String (Enable Ext Modem must be set to Yes)

Do not enable RPS Call Back when using an external modem.

Figure 6: COMMAND 43 Flow Chart

 

 

 

1

 

 

 

2

3

4

 

11

9

11

 

9

10

 

 

6

7

 

 

 

11

 

10

 

 

 

5

8

 

1 -

COMMAND 43

 

7 - Begins RPS session over the network

2 -

Contact RPS?

 

8 - Seizes phone line and begins RPS session

3 -

RPS via Phone?

 

9 - [PREV]

4 - Seizes phone line and calls RPS

 

10 - [NEXT]

5 -

Answer now?

 

11 - [ENT]

6 - RPS by network?

 

 

Bosch Security Systems, Inc. 10/08 F01U003636-04