Bosch Appliances D9412GV2 manual 7.3Event Profile, D# Deact On Open?, D# RTE Shunt Only?, Door #

Models: D9412GV2

1 158
Download 158 pages 17.38 Kb
Page 148
Image 148
D# Deact On Open?

D9412GV2/D7412GV2 Program Entry Guide 7.0 RADXAXS

EN 148

D# Deact On Open?

Default:

Yes

Selection:

Yes or No

Yes

Strike deactivates when the door is

 

opened after a valid Access Granted

 

request.

 

 

No

Strike remains activated for the

 

amount of the programmed strike

 

time whether door is opened or

 

closed.

 

 

Determines if the strike deactivates immediately upon physically opening the door.

In order for this function to work, a point needs to be assigned to the door.

To Reduce False Alarms, maintain D# Deact on Open? as the default (Yes). This helps prevent the door from bouncing open and causing a false alarm.

D# RTE Shunt Only?

Default:

No

Selection:

Yes or No

Yes

Programmed shunt time activates

 

so door can be manually opened.

 

 

No

RTE automatically activates the

 

programmed strike and shunt time.

 

 

Use this program item to disable the strike, but still activate the programmed shunt time at a Request to Enter (RTE) area.

Use this parameter when a user can open a door manually without relying on a token or card to activate the strike (such as with a push bar).

When RTE Shunt Only is Yes, RTE Events are not logged, reported, or printed.

D# REXShunt Only?

Default:

No

Selection:

Yes or No

Yes

Programmed shunt time activates

 

so the door can be manually

 

opened.

 

 

No

REX automatically activates the

 

programmed strike and shunt time.

 

 

Use this program item to disable the door strike, but activate the programmed D# Shunt Time upon a request to exit (REX) from an area.

Use this parameter when a user can open a door manually without relying on a token or card to activate the strike (such as with a push bar).

When REXShunt Only is Yes, REX Events are not logged, reported, or printed.

7.3Event Profile

This programming category is used to determine if events are created for:

Access Granted and Access Denied

Door Requests

Door state changes due to manual (keypad) or automatic scheduled or armed state changes (skeds/hold open on disarm, normal on armed) operation.

Door #

Default: 1

Selection: 1 to 8

Enter the door you plan to program.

RTE Events require Access Granted to be programmed as Yes.

Bosch Security Systems, Inc. 10/08 F01U003636-04