Bosch Appliances D9412GV2 manual Diag Reports

Models: D9412GV2

1 158
Download 158 pages 17.38 Kb
Page 20
Image 20
Diag Reports

D9412GV2/D7412GV2 Program Entry Guide 2.0 GV2MAIN

EN 20

Table 13: Test Reports

Report

Selection

Report

 

s

Description

R# S: Alarm1

Yes, No

Status Alarm

R# S: Trouble1

Yes, No

Status Trouble

R# S:

Yes, No

Status Supervised

Supervised2

 

 

R# Status

Yes, No

Status

Report

 

 

R# S: Open1

Yes, No

Status Open

R# S: Close1

Yes, No

Status Close

R# Test Report

Yes, No

Test

R# S: Perim

Yes, No

Status Perimeter

Inst1

 

Instant Arm

R# S: Perim

Yes, No

Status Perimeter

Delay1

 

Delay Arm

R# S: Fire

Yes, No

Status Fire

Supv2

 

Supervision

R# S: Fire

Yes, No

Status Fire Alarm

Alarm3

 

Report

R# S: Fire Trbl2

Yes, No

Status Fire Trouble

R# S: Msng

Yes, No

Status Fire Missing

Fire2

 

 

R# S:

Yes, No

Status Burg

MsngBurgTr2

 

Missing Trouble

R# S:

Yes, No

Status Burg

MsngBurgAl2

 

Missing Alarm

R# S:

Yes, No

Status Fire

FireSpMsng2

 

Supervision

 

 

Missing

R# S:

Yes, No

Status Non-fire

SuperMsng2

 

Supervision

 

 

Missing

R# S:

Yes, No

Status Door Left

DrLeftOpen2

 

Open

 

 

 

1 Information about this condition is sent with a Status Report.

2 Information about this condition is sent as S: Trouble Event with a Status Report.

3Information about this condition is sent as S: Alarm Event with a Status Report.

Diag Reports

Selecting Yes enables sending a report when the event occurs. If the off-normal state of the events indicated by footnote 1 in Table 14 on page 20 still exists, the events report when a Test Report is enabled and Expanded Test Rpt is programmed Yes. Refer to the Test Reports sub-prompt in Section 2.3.8 Dialing Attempts on page 16.

Table 14: Diagnostic Reports

Report

Selection

Report

 

s

Description

R# SDI Dev Fail1

Yes, No

SDI device

 

 

failure

R# SDI Dev Restl

Yes, No

Restoral of SDI

 

 

device failure

R# Watchdog Rset

Yes, No

Watchdog

 

 

Reset Event

R# ParaChksmFail

Yes, No

Parameter

 

 

checksum

 

 

failure

R# Reboot

Yes, No

Reboot Event

R# Ph Line Fail1

Yes, No

Failure of

 

 

phone line

R# Ph Line Rstl

Yes, No

Restoral of

 

 

phone line

 

 

after failure

R# AC Fail1, 2￿

Yes, No

Failure of AC

 

 

power to

 

 

control panel

R# AC Restorl 2

Yes, No

Restoral of AC

 

 

power to

 

 

control panel

 

 

after failure

R# Batt Missing1, 2

Yes, No

Battery Missing

 

 

Detection

 

 

Event

R# Battery Low1, 2￿

Yes, No

Low battery

 

 

power

R# Battery Rstl 2

Yes, No

Restoral of

 

 

battery power

 

 

to control panel

 

 

after Missing or

 

 

Low Event

R# Rt Comm Fail1,

Yes, No

Failure to send

3

 

report to

 

 

specific route

R# Rt Comm Rstl

Yes, No

Restoral of

 

 

communication

 

 

to specific

 

 

route after a

 

 

failure

Bosch Security Systems, Inc. 10/08 F01U003636-04

Page 20
Image 20
Bosch Appliances D9412GV2 manual Diag Reports