Bosch Appliances D9412GV2 Cross Point Time, Cross Point Ranges Within Groups, Default, 20 sec

Models: D9412GV2

1 158
Download 158 pages 17.38 Kb
Page 143
Image 143
Table 43: Cross Point Ranges Within Groups

D9412GV2/D7412GV2 Program Entry Guide 6.0 GV2AUX

EN 143

Table 43: Cross Point Ranges Within Groups

Cross Point

Point Range

 

Group

 

1

1

to

8

2

9

to

16

3

17

to

24

4

25

to

32

5

33

to

40

6

41

to

48

7

49

to

56

8

57

to

64

9

65

to

72

10

73

to

80

11

81

to

88

12

89

to

96

13

97

to

104

14

105

to

112

15

113

to

120

16

121

to

127

17

129

to

136

18

137

to

144

19

145

to

152

20

153

to

160

21

161

to

168

22

169

to

176

23

177

to

184

24

185

to

192

25

193

to

200

26

201

to

208

27

209

to

216

28

217

to

224

29

225

to

232

30

233

to

240

31

241

to

247

Refer to Section 2.3 Routing on page 15 for information about programming the destination (for example, the central station) for Unverified Events. An Unverified Event does not produce a corresponding Restoral Event.

The Cross Point function applies only to alarm conditions. It does not apply to supervisory or trouble conditions. Points programmed with point response D (Delayed) eventually enter into an alarm condition if the area is not disarmed in time.

Cross Point Time

Default:

20 sec

Selection:

5 sec to 255 sec

 

 

Select the amount of time (in seconds) that points within a Cross Point Group are in alarm before a Cross Point event is generated.

Bosch Security Systems, Inc. 10/08 F01U003636-04

Page 143
Image 143
Bosch Appliances D9412GV2 Cross Point Time, Cross Point Ranges Within Groups, Default, 20 sec, Selection, sec to 255 sec