D9412GV2/D7412GV2 Program Entry Guide 4.0 RADXPNTS

EN 91

P ## Type

Description

 

Selection

 

 

 

D279 (O/C Non-Priority):The D279 provides point arming and disarming independent of the

7*

 

area arm state. A non-priority D279 point arm state does not affect the area arm state. Point

 

Response must be programmed 1. Local bells are silenced through the keypad. For bell

 

control at the D279, use P## Type 8.

 

Open the W1 jumper on the D279 to send Point Opening and Point Closing Reports. If the

 

D279’s W1 jumper is closed, no Open or Close Report is sent, regardless of control panel

 

programming.

 

 

Normal:

The point is armed and sends a Point Closing Report. Point Closing Report is

 

 

not sent if Local Armed is Yes.

 

Open:

The point is disarmed and sends a Point Opening Report. A Point Opening

 

 

Report is not sent if Local Armed is Yes.

 

Short:

A short is an alarm when the point is armed. A short is a trouble when the

 

 

point is disarmed. Alarm and Restoral Reports are not sent if Local

 

 

Disarmed is Yes.

 

 

 

8*

D279 (O/C Priority): The D279 provides point arming and disarming independent of the

 

area’s arming state. A priority D279 point must be armed before an area can be armed.

 

Program Point Response as 2.

 

Open the W1 jumper on the D279 to send area Opening and Closing Reports as programmed

 

in Area Parameters and to provide bell control. If the D279’s W1 jumper is closed, no Area

 

Open or Area Close Report is sent, and alarm bells can only be silenced from a keypad, no

 

matter how the control panel is programmed.

 

Normal:

When this point changes from open to normal, the area arms.

 

Open:

The area is disarmed. The alarm bell silences if an alarm occurred while the

 

 

area was armed.

 

Short:

A short is a trouble while the area is disarmed. A short is an alarm while the

 

 

area is armed. When this point changes from shorted to normal or open, it

 

 

restores.

 

 

 

9*

Easikey: This point is programmed for access. Program Point Response as 1. If the system

 

is Master Armed or Perimeter Armed (with or without delays), presenting a valid token to the

 

Easikey reader shorts the point and disarms its assigned area. Presenting a valid token in a

 

disarmed state does not clear trouble or alarm memory or rearm the area.

11Aux AC Supervision: This point type monitors the AC power of an auxiliary power supply. When the point is in an off-normal state, the control panel waits for the time programmed in AC Fail Time before generating a Point Trouble. If P## Fire Point is set to Yes, the off- normal condition results in a Fire Trouble. This point type does not use P## Point Response; therefore, no alarm condition occurs.

*Keyswitch Points. Special rules apply to points used for Keyswitch functions. These special point types do not respond the same way to the point response entry as Point Types 1, 2, and 3. Responses for keyswitch point types are described in Section 4.2 Point Responses on page 92.

Bosch Security Systems, Inc. 10/08 F01U003636-04