Bosch Appliances D9412GV2 Move to Area, Default Text, Display Rev, Service Walk, Change Skeds

Models: D9412GV2

1 158
Download 158 pages 17.38 Kb
Page 66
Image 66
Move to Area

 

D9412GV2/D7412GV2 Program Entry Guide 2.0

GV2MAIN

 

 

 

 

 

 

 

 

 

 

 

Move to Area

 

 

Default Text

EN 66

Default:

P

 

Selection:

Blank, E, or P

 

 

 

 

Function

Function Name

Alternate

No.

 

Keystroke

30

Move to Area

[COMMAND][5][0]

Use this function to switch the keypad’s assignment temporarily to a different area. This command can be used to perform any function that can be performed by a keypad assigned to the area in programming.

Users are limited to performing functions enabled by the authority level they have in the area to which the keypad is moved. After 15 sec of no activity at the keypad, the keypad reverts back to the originally programmed area.

Display Rev

Default:

E

 

Selection:

Blank, E, or P

 

 

 

 

Function

Function Name

Alternate

No.

 

Keystroke

32

Display Software

[COMMAND][5][9]

 

Revision

 

Use this function to show the control panel’s software revision number in the keypad display.

Service Walk

Default:

P

 

Selection:

Blank, E, or P

 

 

 

 

Function

Function Name

Alternate

No.

 

Keystroke

33

Service Walk

(Menu function

 

Test

only)

Use this function to Walk Test all 246 points in the entire control panel regardless of the P## Type.

The Service Walk Test is available on the D9412GV2 using the Service Menu [9][9][ENT]. The D7412GV2 does not include the Service Walk Test in the Service Menu. In the D7412GV2, the Service Walk Test function must be enabled in the Function List to access the Service Walk Test.

Default:

 

P

 

Selection:

 

Blank, E, or P

 

 

 

 

 

Function

 

Function Name

Alternate

No.

 

 

Keystroke

34

 

Default Text

[COMMAND][5][7]

Determining the armed state of an area using the programmed custom text might be difficult. Use this function to switch temporarily to the control panel default text, shown on the program record sheet.

Change Skeds

Default:

 

P

 

Selection:

 

Blank, E, or P

 

 

 

 

 

Function

 

Function Name

Alternate

No.

 

 

Keystroke

35

 

Change Skeds

[COMMAND][5][2]

Execute this panel-wide function from any keypad assigned to an area where the user has authority. Use this function to change the S## Time from the keypad to make adjustments to Skeds.

Invisible Walk Test

Default:

 

P

 

 

Selection:

 

Blank, E, or P

 

 

 

 

Function Name

 

 

Function

 

Alternate

No.

 

 

Keystroke

36

 

Invisible Walk Test

(Menu function only)

This function allows a user with the L## Invisible Walk Test authority to test invisible interior or perimeter controlled points that are within the scope of the keypad, without sending reports to the central station. Invisible points must have the P## Invisible Pt function programmed Yes.