Bosch Appliances D9412GV2 S## Cmd Center 1through, S## Access Ctl Level #, S## Access Ctl Level#

Models: D9412GV2

1 158
Download 158 pages 17.38 Kb
Page 120
Image 120
S## Cmd Center 1[through 8]

D9412GV2/D7412GV2 Program Entry Guide 5.0 RADXSKED

Default: Blank

EN 120

Selection:

 

1 to 11, 13 to 24, 28, 29

 

 

 

 

15

Sound Watch Tone at

 

S## Cmd Center 1[through 8]

Ye

Watch tone sounds

 

 

Command Center (Keypad): This

 

s

at this keypad.

 

 

 

Default: Blank

 

 

function sounds the Watch Tone

 

 

 

 

 

at the keypad address

 

Selection: Yes or No

No

Watch tone does

 

 

programmed in Parameter 1. The

 

Enable the sked to beep the keypad

 

not sound at this

 

 

Watch Tone sounds at all

 

 

keypad.

 

 

 

programmed Yes.

 

 

 

keypads with the address

 

 

 

 

 

 

 

 

 

 

 

programmed. Press [ESC] to

 

 

 

 

 

 

silence the tone.

 

 

 

 

 

 

Sound Watch Tone defines the

 

 

 

 

 

 

keypad address where the Watch

 

 

 

 

 

 

Tone sounds. Enter the specific

 

 

 

 

 

 

address at the S## Cmd Center

 

 

 

 

 

 

prompt.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

Access Control Level On: This

 

S## Access Ctl Level #

Ye

Enable Access

 

 

function emulates the ACCESS

 

s

Control Level #

 

 

 

Default: No

 

 

CMD LEVEL command that

 

 

 

 

 

determines whether a user’s

 

Selection: Yes or No

No

Do not enable

 

 

token or card level is ENABLED?,

 

 

 

 

Activate a sked, which enables the

 

Access Control

 

 

allowing access granted rights.

 

 

 

 

 

 

Level #.

 

 

 

Access Level(s) 1 through 14 with

 

 

 

This affects all doors that this

 

 

 

 

 

 

 

 

 

 

Yes.

 

 

 

 

user is assigned to with this

 

 

 

 

 

 

 

 

 

 

 

specific authority level.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The D9412GV2 supports eight doors; the D7412GV2 supports two doors.

To regulate a user’s access for certain doors, assign the user a different authority level # with the same authority functions enabled. For example, a user can be assigned Authority Level 1 for Door 1 and Authority Level 2 for the remaining doors. You can enable or disable Authority Level 1 for Door 1 without affecting his authority level for Doors 2 through 8).

Default:

Blank

 

 

 

 

Selection:

1 to 11, 13 to 24, 28, 29

 

 

 

 

17

Access Control Level Off:

S## Access Ctl Level#

Yes

Turn off access for

 

This function emulates the

 

level #.

 

Default: No

 

 

ACCESS CMD LEVEL

 

 

 

 

command that determines

Selection: Yes or No

No

Do not turn off

 

whether a user’s token or card

 

The first parameter enables the sked

 

access for level #.

 

level is disabled. This function

 

 

 

 

 

 

to turn off access for Levels 1 through

 

 

 

 

allows access to be turned off

 

 

 

 

14.

 

 

 

 

for the levels programmed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

Unlock Door: This function

S## Door 1 [through 8]

Yes

Unlock Door #.

 

 

emulates the UNLOCK?

 

 

 

 

Default: No

 

 

 

 

12345678 keypad function for

 

 

 

 

unlocking a door.

Selection: Yes or No

No

Do not unlock

 

 

 

 

Enable the sked to unlock the doors

 

Door #.

 

 

 

 

 

 

 

 

 

 

programmed Yes.

 

 

 

 

 

 

 

 

 

 

Bosch Security Systems, Inc. 10/08 F01U003636-04