Bosch Appliances D9412GV2 manual User Windows #, UW# User Group, Delivery Schedule

Models: D9412GV2

1 158
Download 158 pages 17.38 Kb
Page 113
Image 113
Table 41: Delivery Schedule*

D9412GV2/D7412GV2 Program Entry Guide 5.0 RADXSKED

EN 113

Table 41: Delivery Schedule*

W#

3

Day of Week

S M T W T F S

Program at least one day Yes.

Open

Close

Early

 

Start

 

Stop

Early

Start

 

Stop

Begin

 

 

Begin

 

02 : 30

 

02 : 45

 

03 : 00

03 : 05

03: 15

 

03: 30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00 : 00

01 : 00

 

Day(s) of the week, but not on holidays

 

 

 

 

 

 

 

 

 

 

 

eXcept

On

Holiday

Yes No

Yes No Yes

Holiday

Index

1 2 3 4

1 2 3 4

Select at least one index

Area(s)

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

Program at least one area Yes.

*Monday and Wednesday, In between 2:45 AM and 3:00 AM. Out between 3:15 AM and 3:30 AM. Another alternative for delivery schedules is to automatically bypass specific points using skeds.

Table 42: Monthly Auditor’s Schedule*

W#

4

Day of Week

S M T W T F S

All days must be programmed No.

Open

Close

Early

 

Start

 

Stop

Early

Start

 

Stop

Begin

 

 

Begin

 

07 : 00

 

08 : 00

 

08 : 30

14 : 00

14: 30

 

17: 00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Only on holidays

eXcept

On

Holiday

Yes No

No

Holiday

Index

1 2 3 4

Select at least one index

Area(s)

1 2 3 4 5 6 7 8

Program at least one area Yes.

*Sunday, In between 8:00 AM and 8:30 AM. Out between 2:30 PM and 5:00 PM..

5.1.2User Group Windows

In this section, you can create up to eight User Group periods where the pass codes for the group chosen is enabled. One user group can have multiple windows assigned to it over a 24-hour period. Refer to the U### User Group prompt in Section 3.1 Pass Code or Token Worksheet to assign individuals to a group.

When you assign a U### User Group to one of the eight windows, all pass codes for the group are enabled ONLY for the period between the Enable Time and Disable Time for assigned User Windows

#.

If a user is not assigned to a U### User Group or the number programmed for the user for U### User Group is not assigned to a User Windows #, the pass code for that user is enabled all the time.

User Group Windows do not affect the users token or card access authority. To enable/disable tokens, the Sked Function Access Levels On/Off must be used.

User Windows #

Default: 1

Selection: 1 to 8

Enter the User Windows number you want to program.

UW# User Group

Default: 1

Selection: Blank, 1 to 8

Enter the number programmed for the group of users in the U### User Group prompt. This group has its user pass codes enabled or disabled when this window runs.

A User Group can be assigned to more than one window in a 24-hour period, but the windows must not overlap or exceed the midnight boundary.

Bosch Security Systems, Inc. 10/08 F01U003636-04