D9412GV2/D7412GV2 Program Entry Guide 6.0 GV2AUX

EN 126

6.0GV2AUX

6.1Introduction

The GV2AUX Handler is used primarily for programming Enhanced Communication capabilities for the 9000GV2 Series Control Panels.

“Enhanced communications” represents the ability to provide new communication functions for the control panels using the SDI bus including:

Routing control panel events to a network interface module (NIM).

A network interface module (NIM) can be a D9133TTL-E or a DX4020.

Communicating with remote programming software (RPS) using a network interface module (NIM).

Communicating with a remote or local automatic software package.

6.2RPS and D5200 Handler Requirements

In order to program the GV2AUX parameters for the control panels, you must use RPS version 3.8 or higher and a handler called GV2AUX. To add the GV2AUX Handler to your D5200 Programmer, call the Bosch Security Systems, Inc. Handler Update System at

(800) 657-4584.

This handler currently has six sections:

SDI Automation

SDI RPS Parameters

Enhanced Communications

SDI RPS/Enhanced Communication Configuration

Miscellaneous

Cross Point Parameters

The handler required for these options is GV2AUX version 1.0 and above. It is available on the Handler Update System at Bosch Security Systems, Inc.

6.3SDI Automation

SDI automation defines the characteristics of a serial interface module (SIM) when used with home or business automation software. The SIM is a two-way SDI to a serial communication module that allows the control panels to send and receive information to and from an external software program.

The SIM can be a D9133, DX4010i, or DX4020 (configured to emulate serial communication).

This automation protocol allows external software programs to interact and perform functions such as:

arming and disarming areas,

changing user pass codes and names, and

turning relays on and off.

The items described in this section allow some simple configuration options. To receive the SIM automation protocol; however, you must contact Bosch Security Systems, Inc. Technical Support at (888) 886-6189.

Enable SDI Auto

Default:

No

Selection:

Yes or No

Yes

Enable Automation software.

 

 

No

Disable Automation software.

 

 

Changing this item to Yes enables the automation address (SDI Address 80).

Baud Rate

Default:

9600

Selection:

300, 1200, 2400, 4800, 9600, 14.4

 

K

 

 

This item determines the baud rate between the serial interface module (SIM) and the external hardware connected to it. Since the SDI bus communicates at 9600 baud, keep this prompt at 9600 baud. Pressing the [SPACE] bar on the D5200 toggles through the available options.