P## Entry Delay

D9412GV2/D7412GV2 Program Entry Guide 4.0 RADXPNTS

EN 94

P## Entry Delay

Default:

Refer to the program record sheet

Selection:

5 sec to 600 sec

 

 

Use this option to enter the amount of entry delay time that a user has after faulting a Controlled point (P## Type 1, 2, 3) with a delayed response (D) (P## Pt Response) of 4, 5, 6, 7, or 8. DISARM NOW appears for the duration of the time programmed when the point is faulted in the delay condition.

The D1255 alternates between DISARM NOW and the point text of the point that caused the area to enter into entry delay.

If this time expires before disarming, or if the point is configured with an instant response (I), an alarm occurs.

Make entries in 5 sec increments. The programmer does not allow off-increment entries.

When the control panel is in Entry Delay, entering a valid Passcode disarms the system as soon as the last digit of the Passcode is entered. No other keys are required. When the control panel is in Exit Delay or is armed, entering a valid Passcode must be followed by the [ENTER] or [ENT] key.

If another Perimeter or Interior Follower Delay point trips while the area is already in entry delay, the control panel adjusts the delay time to the Delay point with the least amount of delay time.

When a user enters an area, a Perimeter point is faulted and the entry delay starts. If an interior point must fault during entry delay to allow the user to disarm the area at a keypad, program P## Type as 3 (Interior Follower).

For SIA CP-01 Compliance:

P## Entry Delay must be between 30 sec and 240 sec.

P## Ent Tone Off

Default:

 

No

Selection:

 

Yes or No

Yes

 

Disables the entry delay tone when

 

 

this perimeter point is faulted.

 

 

This is intended for use with points

 

 

set to P## Type 1 (Perimeter).

 

 

A tone sounds at keypads when this

No

 

 

 

point starts entry delay.

 

 

 

This option enables and disables the entry delay warning tone for this point.

Do not set points to No if they are actually used to notify the user to disarm the system. The possibility of false alarms increases if the entry delay warning is not used.

Entry Tone can also be turned off when programming your CC Entry Tone, in Section 2.10 Keypad (Command Center) on page 51, that allows you to manage the tone by keypad.

You might want to disable the entry tone in high security applications where you do not want to annunciate entry delay.

P## Silent Bell

Default: No

Selection: Yes or No

 

Yes

 

Activate the Silent Alarm Relay when

 

 

 

this point enters into alarm. Keypads

 

 

 

do not sound the alarm tone for Non-

 

 

 

fire points.

 

 

 

Activate either the Fire Bell relay or

 

No

 

 

 

 

Alarm Bell relay and sound the alarm

 

 

 

tone at keypads when this point

 

 

 

enters into alarm. If this is a Fire

 

 

 

point, it activates the Fire Bell relay

 

 

 

programmed in Relay Parameters.

 

 

 

Otherwise, it activates the Alarm Bell

 

 

 

relay. The amount of time and

 

 

 

pattern of the relay activation is

 

 

 

programmed by area in Bell

 

 

 

Parameters.

 

 

 

 

 

 

 

 

 

To meet UL 864 requirements, set this

 

 

 

 

parameter to No.

 

 

 

 