Bosch Appliances D9412GV2 CC# Area Assign, CC# Scope, CC# A1through A8 in Scope, CC# Entr Key Rly

Models: D9412GV2

1 158
Download 158 pages 17.38 Kb
Page 52
Image 52
CC# Area Assign

D9412GV2/D7412GV2 Program Entry Guide 2.0 GV2MAIN

EN 52

CC# Area Assign

Default: 1

Selection: 1 to 8

Blank is not a valid entry.

Enter the area number where you are installing this keypad or keypads with this address and the same DIP switch settings.

CC# Scope

Default:

Refer to the program record sheet

Selection:

Panel Wide, Custom, No Keypad,

 

Area, and Account

Panel

A panel-wide keypad can view

Wide

information and perform Arming and

 

Disarming functions for all areas in

 

the control panel. A panel-wide

 

keypad can cross account

 

boundaries. This is normally used

 

with a master area.

 

 

Account

An Account keypad can view

 

information, and perform Arming and

 

Disarming functions for all areas with

 

the same A# Acct Number, in Area

 

Parameters. This is normally used for

 

an associate area.

 

 

Area

An area keypad is restricted to

 

viewing information and Arming or

 

Disarming functions for the area to

 

which it is assigned.

 

 

Custom

A custom keypad has no keypad

 

restrictions.

 

 

No

No keypad installed at this address.

Keypad

CALL FOR SERVICE display shows,

 

indicating the control panel is not

 

polling this address.

 

 

This program item is used to define the areas affected when an arming command is executed on this keypad, the areas this keypad can view, and the areas to which this keypad can move.

Press the [SPACE] bar to scroll through the selections. Press [ENTER] when the correct selection appears in the display.

In applications where keypads include more than one area, active alarms in remote areas must be acknowledged before arming or disarming the local area.

The following prompt is visible only when you program CC## Scope to Custom. If you change the keypad scope selection to Custom from Panel Wide, Account, or Area, the settings from the previous CC# Scope selection become the default settings for the custom parameters in CC# A1 [through A8] in Scope. Before exiting from a custom program, check each area and ensure that it is enabled and disabled correctly.

CC# A1[through A8] in Scope

Default:

Refer to the preceding important

 

note

Selection:

Yes or No

Yes

Include this area in the scope of this

 

keypad.

 

 

No

Do not include this area in the scope

 

of this keypad.

 

 

Determines whether any of the eight areas (Area 1 to Area 8) and Doors (Door 1 to Door 8) are included in the scope of this keypad for viewing status, arming or disarming, and controlling doors from the keypad.

CC# Entr Key Rly

Default:

Blank

Selection:

1 to 128, A, B, C, and Blank

Blank

The [ENTER] key is not used to

 

activate a relay.

 

 

1 to 128,

Assign the relay number that

A, B, C

activates when [ENTER] is pressed at

 

this keypad after the user enters a

 

valid pass code.

 

 

Enter Key Relay: Program the relay number that activates momentarily for 10 sec when a user enters a valid pass code and presses the [ENTER] key on the keypad. Two events are generated when this function is used: RELAY ### SET with User ID, and RELAY

###RESET without User ID. The system logs this action as two events.

Entering a valid code and pressing [ENTER] silences a ringing bell.

Using CC# Entr Key Rly for a low-level access control strike on a door does not shunt a point.

Bosch Security Systems, Inc. 10/08 F01U003636-04

Page 52
Image 52
Bosch Appliances D9412GV2 manual CC# Area Assign, CC# Scope, CC# A1through A8 in Scope, CC# Entr Key Rly