Bosch Appliances D9412GV2 manual P## Local While Armed, P## Disable Rst, P## FA Retrnable

Models: D9412GV2

1 158
Download 158 pages 17.38 Kb
Page 98
Image 98
P## Local While Armed

D9412GV2/D7412GV2 Program Entry Guide 4.0 RADXPNTS

EN 98

Local While Disarmed suppresses all reports from 24-hour points. Do not use P## Type 0 for this prompt. Remember that this option works only for Disarmed points, and a Type 0 is a 24-hour Always Armed point. Instead, choose any type other than 0, and use a point response that reports an alarm, whether or not the point is armed. For instance, P## Type 1 and P## Response 9 reports an alarm on an open or a short (I) whether the area is armed or not.

Local While Disarmed affects Keyswitch points. This prompt suppresses keyswitch (troubles and restorals) and D279 (alarms, troubles, and restorals). Do not use this parameter for these applications.

Local While Armed suppresses all reports from 24-hour points. Do not use P## Type 0 for this prompt. This setting works only for disarmed points. Type 0 is a 24-hour, always armed point. Choose any Type other than 0, and use a point response that reports an alarm whether or not the point is armed. For instance, P## Type 1 and P## Response 9 reports an alarm on a trouble or a short whether or not the area is disarmed.

Local While Armed affects Keyswitch Points. This prompt suppresses keyswitch (alarms, troubles, and restorals) and D279 (opening, closing, troubles, and restorals). Do not use this parameter for controlled points that arm or disarm.

P## Local While Armed

Default:

No

Selection:

Yes or No

Yes

Suppress Alarm, Trouble and

 

Restoral* Reports from this point

 

while the area to which it is assigned

 

is armed.

 

 

No

Report events occurring from this

 

point while the area is armed.

 

 

*Transmission of Restoral Reports continues if the alarm, trouble, or bypass (by Sked, RPS, or Swinger bypass) condition occurred when the area disarmed, and the point restored.

To meet UL 864 requirements for Central Station and Remote Station applications, set this parameter to No.

Allows a controlled point (P## Type 1, 2, 3), to report Alarms, Troubles, and Restoral Reports only when the area is disarmed. This prompt does not affect local annunciation.

P## Disable Rst

Default: No

Selection: Yes or No

Yes

Enable Restoral Reports from this

 

point.

 

 

No

Disable Restoral Reports from this

 

point.

 

 

To meet UL 864 requirements for Central Station and Remote Station applications, set this parameter to No.

Use this option to disable any Restoral Reports from this point after it returns to normal from an alarm or trouble condition.

P## FA Retrnable

Default:

No

Selection:

Yes or No

Yes

This point automatically returns to the

 

system when it restores to normal.

 

 

No

This point stays out of the system

 

until the area is disarmed.

 

 

Use this option to allow points that were force armed out of the area to return back to the armed state when they become normal again without having to disarm the system.

Use on loading dock doors, that must remain open until loading is completed. After the loading dock door is closed, the point detects any subsequent opening and reports an alarm.

Bosch Security Systems, Inc. 10/08 F01U003636-04