AC Fail Display

D9412GV2/D7412GV2 Program Entry Guide 2.0 GV2MAIN

EN 29

When you program AC Fail Time, if the second digit is:

1, 3, or 5 (such as 3, 5, 11, 13, 15, 21, and so on): The AC Fail Time interval is in minutes and an AC Fail Event is sent after the loss of AC for this amount of time.

No additional AC Fail Events are sent after 6 hours or 12 hours.

2, 4, or 6 (such as 2, 4, 6, 12, 14, 16, 22, 24, 26, and so on): The AC Fail Time interval is in seconds and an AC Fail Event is sent after the loss of AC for this amount of time.

No additional AC Fail Events are sent after 6 hours or 12 hours.

7 (such as 7, 17, 27, 37, and so on): The AC Fail Time interval is in minutes and an AC Fail Event is sent after the loss of AC for this amount of time.

An additional AC Fail Event is sent after 6 hours if the AC Fail condition is still present.

8 (such as 8, 18, 28, 38, and so on): The AC Fail Time interval is in seconds and an AC Fail Event is sent after the loss of AC for this amount of time.

An additional AC Fail Event is sent after 6 hours if the AC Fail condition is still present.

9 (such as 9, 19, 29, 39, and so on): The AC Fail Time interval is in minutes and an AC Fail Event is sent after the loss of AC for this amount of time.

An additional AC Fail Event is sent after 12 hours if the AC Fail condition is still present.

0 (such as 10, 20, 30, and so on): The AC Fail Time interval is in seconds and an AC Fail Event is sent after the loss of AC for this amount of time.

An additional AC Fail Event is sent after 12 hours if the AC Fail condition is still present.

For the following items to be true, AC Fail/Res Rpt must be programmed as No and AC Tag Along must also be programmed as No.

When you program AC Fail Time, if the second digit is:

1, 3, or 5 (such as 3, 5, 11, 13, 15, 21, and so on): The AC Fail Time interval is in minutes. No AC Fail or AC Restoral Events are sent.

2, 4, or 6 (such as 2, 4, 6, 12, 14, 16, 22, 24, 26, and so on): The AC Fail Time interval is in seconds. No AC Fail or AC Restoral Events are sent.

7 (such as 7, 17, 27, 37, and so on): The AC Fail Time interval is in minutes. An AC Fail Event is only sent after 6 hours if the AC Fail condition is still present.

8 (such as 8, 18, 28, 38, and so on): The AC Fail Time interval is in seconds. An AC Fail Event is only sent after 6 hours if the AC Fail condition is still present.

9 (such as 9, 19, 29, 39, and so on): The AC Fail Time interval is in minutes. An AC Fail Event is only sent after 12 hours if the AC Fail condition is still present.

0 (such as 10, 20, 30, and so on): The AC Fail Time interval is in seconds. An AC Fail Event is sent after 12 hours only if the AC Fail condition is still present.

To eliminate AC Reporting, AC Tag Along and AC Fail/Res Rpt must be programmed as No and the second digit of the AC Fail Time must be a 1, 2, 3, 4, 5, or 6.

AC Fail Display

Default:

60 sec

Selection:

10 to 300 sec (in 5-sec

 

increments)

 

 

Program the length of time the AC power must be off before the message SERVC AC FAIL shows on the keypads. The response to restoral of AC power is delayed for the same amount of time.

AC Fail/Res Rpt

Default:

No

Selection:

Yes or No

Yes

Send AC Fail and AC Restoral

 

Reports.

 

 

No

Does not send AC Fail and AC

 

Restoral Reports.

 

 

AC Power Supervision Reports are sent to the central station and local printer at the time programmed for AC Fail Time.