Bosch Appliances D9412GV2 manual CC# Trouble Tone, CC# Entry Tone, CC# Exit Tone, CC# Arm Now Warn

Models: D9412GV2

1 158
Download 158 pages 17.38 Kb
Page 54
Image 54
CC# Trouble Tone

D9412GV2/D7412GV2 Program Entry Guide 2.0 GV2MAIN

EN 54

CC# Trouble Tone

Default:

Yes

Selection:

Yes or No

Yes

Panel-wide trouble tones sound and

 

visual displays show at this keypad.

 

 

No

Panel-wide troubles do not sound.

 

Visual displays still show.

 

 

Determines whether this keypad, or any keypad with the same address setting, emits the panel-wide trouble tones (power, phone, SDI bus, and Zonex bus).

To meet UL 864 requirements, set CC#

Trouble Tone to Yes.

Panel-wide trouble tones do not include

Point Troubles, Buzz on Fault, or Close

Door Now.

Assign two CCs to the same area so one keypad emits the tone and another does not.

CC# Entry Tone

Default:

Yes

Selection:

Yes or No

Yes

This keypad sounds entry tones.

 

 

No

This keypad does not sound entry

 

tones.

 

 

Determines whether this keypad, or any keypad with the same address setting, emits the entry delay tone. Any Delay point within the area scope of this keypad starts the entry sequence.

This prompt allows you to manage the tone by keypad. Entry Tone can also be turned off when programming your P## Entry Tone off in Point Index.

Assign two CCs to the same area so one keypad emits the tone and another does not.

For SIA CP-01 Compliance

CC# Entry Tone can be set to Yes or No.

CC# Exit Tone

Default:

Yes

Selection:

Yes or No

Yes

This keypad sounds entry tones.

 

 

No

This keypad does not sound entry

 

tones.

 

 

Determines whether this keypad, or any keypad with the same address setting, emits the exit delay tone during the delay arming of an area(s). Any keypad with a scope to arm this area can initiate the exit tone sequence.

This prompt allows you to manage the tone by keypad. Exit Tone can also be turned off when programming A# Exit Tone in Area Parameters.

The cadence and pitch of the exit tone increase for the last 10 sec of the exit delay time.

This SIA CP-01 required feature is not supported on the D720 and D720B Keypads.

Assign two CCs to the same area so one keypad emits the tone and another does not.

For SIA CP-01 Compliance

CC# Exit Tone can be set to Yes or No.

CC# Arm Now Warn

Default:

No

Selection:

Yes or No

Yes

This keypad activates a tone and

 

displays PLEASE CLOSE NOW.

 

 

No

This keypad does not activate the

 

tone or display PLEASE CLOSE

 

NOW.

 

 

Determines whether this keypad sounds a tone and displays the PLEASE CLOSE NOW warning on the keypad when a Closing Window activates, indicating the area automatically arms soon.

Bosch Security Systems, Inc. 10/08 F01U003636-04

Page 54
Image 54
Bosch Appliances D9412GV2 manual CC# Trouble Tone, CC# Entry Tone, CC# Exit Tone, CC# Arm Now Warn, Trouble Tone to Yes