A# Exit Restart

D9412GV2/D7412GV2 Program Entry Guide 2.0 GV2MAIN

EN 49

Parameter Setup Requirement:

The Early Ambush timer can be started and stopped only by pass codes with the L## Passcode Disarm authority.

To avoid unintended results for the end user of the system:

When a keypad is assigned to an area that has the Early Ambush feature enabled, set the CC# Scope value to Area Wide.

If an area has A# Two Man Rule set to Yes, do not set A# Early Ambush to Yes.

During an alarm, after the first pass code is entered, the Early Ambush timer still begins. A Cancel Report might be generated, depending upon the bell time, and the keypad displays Alarm Silenced normally. If the second valid disarm pass code is entered, the keypads indicate that the second pass code is valid. Refer to the Secondary Ambush Code prompt on page 140 for information about the unique behavior of the two pass codes.

For SIA CP-01 Compliance:

This feature is not allowed for use with

SIA CP-01 compliant installations.

A# Exit Restart

Default: Yes

Selection: Yes or No

 

Yes

 

Delay armed points in this area

 

 

 

restart the exit delay timer if violated

 

 

 

during the exit delay time.

 

 

 

 

 

No

 

Delay armed points continue to count

 

 

 

down normally if violated during the

 

 

 

exit delay time.

 

 

 

 

 

 

 

 

 

This feature must be disabled for UL Line

 

 

 

 

 

 

Security/Encryption applications.

 

 

 

 

 

 

 

 

When enabled, this feature activates when a controlled point with delay alarm response changes from normal to faulted and back to normal during the exit delay. When activated, if any controlled point in the same area with delay alarm response is faulted, the exit delay time restarts. The exit delay continues until it expires or the area changes arming states. This operation can occur only once in an arming cycle.

To avoid the possibility of false alarms in Associate areas, do not use the A# Exit Restart feature in areas with A# Area Type set to Shared.

For SIA CP-01 Compliance

This prompt can be set to Yes or No.

A# Arm No Exit

Default:

Yes

Selection:

Yes or No

Yes

Switch the arming state to Perimeter

 

if no Perimeter Delay point faults

 

occurred.

No

Keep the area in Master Arm if no

 

Perimeter Delay point faults

 

occurred.

 

 

This parameter switches the arming state of an area from Master Armed to Perimeter Armed if no perimeter points with delay response were activated during the exit delay time. Only the final armed state is reported and displayed at the keypads.

The A# Arm No Exit feature does not operate in areas with A# Area Type set to Shared.

For SIA CP-01 Compliance:

A# Exit Restart can be set to Yes or No.

A# Exit Warning

Default:

 

Yes

Selection:

 

Yes or No

Yes

 

Pulse the alarm output for the last 10

 

 

sec of the Exit Delay time.

No

 

Do not pulse the Alarm Bell output

 

 

during the Exit Delay time.

 

 

 

When enabled, the Alarm Bell output pulses on and off every 2 sec for the remaining 10 sec of the Exit Delay time.

For SIA CP-01 Compliance

A# Exit Warning must be set to Yes.