1.2Product Handlers

D9412GV2/D7412GV2 Program Entry Guide 1.0 Introduction

EN 6

1.2Product Handlers

Programming the 9000GV2 Series requires multiple product handlers. The availability of each handler is indicated in Table 3. Refer to the specific control panel’s release notes to determine the most current handler versions.

Although the handlers shown in Table 3 can be used to program any of the new control panels, not all of the functions operate. For example, the RADXUSR1 Handler programs users 000 through 124. Even though the handler allows you to program users 100 through 124, the D7412GV2 does not allow the activation of these users.

Table 3: Product Handlers

 

Product

Compatible

Function

 

D9412GV2

 

D7412GV2

 

Handler

Versions

 

 

 

 

 

 

 

 

GV2MAIN

 

V1.03 and above

 

Covers Panel-Wide, Area, Keypad

 

9

 

 

9

 

 

 

 

 

 

Function List, User Interface, and

 

 

 

 

 

 

 

 

 

 

 

Relay programming modules.

 

 

 

 

 

 

 

RADXUSR1

V1.06 and above

Covers passcode and token

9

 

9

 

 

 

 

 

 

programming for users 000 through

 

 

 

 

 

 

 

 

 

 

 

124

 

 

 

 

 

 

 

 

 

 

 

(users 000 through 099 for the

 

 

 

 

 

 

 

 

 

 

 

D7412GV2).

 

 

 

 

 

 

 

RADXUSR2

 

V1.05 and above

 

Covers passcode and token

 

9

 

 

N/A

 

 

 

 

 

 

programming for Users 125 through

 

 

 

 

 

 

 

 

 

 

 

249.

 

 

 

 

 

 

 

RADXPNTS

V1.08 and above

Covers Point Index and Point

9

 

9

 

 

 

 

 

 

Assignment programming for all

 

 

 

 

 

 

 

 

 

 

 

points.

 

 

 

 

 

 

 

RADXSKED

 

V1.04 and above

 

Covers Open/Close Windows, User

 

9

 

 

9

 

 

 

 

 

 

Access Windows, Skeds, and Holiday

 

 

 

 

 

 

 

 

 

 

 

Index programming modules.

 

 

 

 

 

 

 

GV2AUX

V1.03 and above

Covers SDI Automation, SDI RPS

9

 

9

 

 

 

 

 

 

Parameters, Enhanced

 

 

 

 

 

 

 

 

 

 

 

Communication Parameters, Route

 

 

 

 

 

 

 

 

 

 

 

Group Attempts, Miscellaneous, and

 

 

 

 

 

 

 

 

 

 

 

Cross Point Parameters.

 

 

 

 

 

 

 

RADXAXS

 

V1.06 and above

 

Covers the programming parameters

 

9

 

 

9

 

 

 

 

 

 

for installed D9210B Door Controllers.

 

 

 

 

 

 

The program entry guide and program record sheet for this handler come with the D9210B Access Control Module.