Bosch Appliances D9412GV2 manual 2.12Function List, Menu Item, M## Function, #6 Watch Mode

Models: D9412GV2

1 158
Download 158 pages 17.38 Kb
Page 77
Image 77
L## Disarm set to E

D9412GV2/D7412GV2 Program Entry Guide 2.0 GV2MAIN

EN 77

2.11.6 SIA Duress Passcode Options

GV2MAIN→USER INTERFACE→ Authority Levels

→L## Disarm

GV2MAIN→ USER INTERFACE→ Authority Levels

→L## Send Duress

GV2MAIN→ USER INTERFACE→ Authority Levels

→L## Passcode Disarm

General Programming Information

User Authority Index 14 is programmed by default as a duress disarm profile. When Duress Option is configured with a value of 3, the SIA CP-01 compliant Duress Passcode feature is enabled. With Authority Index 14 assigned to a user passcode in an area, that user has the authority to disarm and send a duress event from that area.

A Duress Disarm user authority index requires:

L## Disarm set to E

L## Send Duress set to E

L## Passcode Disarm set to E

For SIA CP-01 Compliance

Duress Types 1 and 2 (refer to Duress Type on page

35)are not allowed for use in SIA CP-01 compliant installations. All duress-capable passcodes must be unique and cannot be derived from other passcodes. To facilitate this uniqueness, user Authority Index 14 is preprogrammed from the factory as an example of duress disarm authority.

2.12Function List

The Function List is accessed when the user presses [MENU] (or the key corresponding to menu on the D1260) while the keypad shows the idle text. Program as many as 32 M### Function(s).

Each CC # keypad address can display a combination of any of the 32 menu items. The D1255 displays one menu item at a time. The D1260 displays up to two menu items at a time. Each keypad address has one Function List. The function name shown in the Functions column in the program record sheet appears in the keypad display in capital letters. For example, WATCH MODE appears when you select

#6 Watch Mode.

Menu Item

Default:

 

Refer to the program record sheet

Selection:

 

1 to 32

 

 

 

Enter the menu item number you are programming. The M## Function displays items sequentially in the order they are programmed. The M1 Function is the first function that appears in the menu and M32 Function is the last function that appears when scrolling through the menu.

Failing to program Menu Item 1 causes COMMAND DISABLED to appear in the keypad display.

M## Function

Default:

 

Refer to the program record sheet

Selection:

 

Blank, 1 to 30, 32 to 35, 37, and

 

 

128 to 143

 

 

 

Enter the function number indicated in the “#” column of the program record sheet or next to the function in Section 2.11 User Interface on page 60.

Function numbers 128 to 143 are custom functions and show the text programmed for CF ### Text.

There is no restriction on how many times you can assign a specific function to the menu. By assigning a specific function more than once, you can assign the same function at different keypads so that their order is different in different areas.

Bosch Security Systems, Inc. 10/08 F01U003636-04