D9412GV2/D7412GV2 Program Entry Guide 4.0 RADXPNTS

EN 100

P## Swinger Byps

Default: No

Selection: Yes or No

 

Yes

 

Enable Swinger Bypass for this point.

 

 

 

 

 

No

 

Disable Swinger Bypass for this

 

 

 

point.

 

 

 

 

 

 

 

 

 

To meet UL requirements, set this

 

 

 

 

parameter to No.

 

 

 

 

Use the P## Swinger Byps parameter to allow the control panel to bypass automatically a point that reports two or more alarm or trouble events within the same arm cycle. The maximum number of faults allowed on a point is set in the Swinger Count prompt (refer to page 141).

The control panel reports a Swinger Bypass when the Swinger Count is reached and P## Report Bypass at Occurrence is set to Yes. If the point has a partial count (less than the Swinger Count number of events during an hour), the count is reset to zero.

P## Bypassable does not need to be programmed as Yes for swinger bypass to work.

A Swinger Shunted point returns to the system if P## BP Returnable? is Yes. If not, return the point to the system through manual unbypass or [COMMAND][0][0]. Refer to P## BP Retrnable in the program entry guide for additional information.

P## Report Bypass at Occurrence

Default:

No

Selection:

Yes or No

Yes

Send a Command Bypass Report

 

when the point is bypassed.

 

 

No

Do not send a Command Bypass

 

Report when the point is bypassed.

 

 

Send a Command Bypass Report as soon as a user bypasses the point from the keypad. Enable this option for all Bypassable 24-hour points. You can also report a bypassed point at the time the area is armed. Refer to P## Defer BP Report on page 100.

P## Defer BP Report

Default:

No

Selection:

Yes or No

Yes

Send a Point Bypass Report with the

 

Closing Report instead of a

 

Command Bypass Report when a

 

user bypasses the point.

 

 

No

Do not defer Bypass Reports.

 

 

Use this option to prevent P## Type (0 to F) points that are bypassed by the user (COMMAND BYPASS) from occurring until the area is armed. When the area is armed, the bypassed points and any point being bypassed during the arming sequence report as POINT BYPASS along with the Closing Report.

When P## Defer BP Report is set to Yes and Closing Reports are suppressed by using Closing Windows, the deferred Bypass Reports are not sent.

Bypass Reports for 24-hour points do not report If P## Report Bypass at Occurrence and P## Defer Bypass Report are both set to No.

To report the bypass at occurrence and when the area is armed, program P## Report Bypass at Occurrence and P## Defer Bypass Report as Yes. A Command Bypass Report is sent as soon as the user manually bypasses a point, and a supplemental Point Bypass Report is sent with the Closing Report.

P## Cross Point

 

Default:

 

No

 

Selection:

 

Yes or No

 

Yes

 

This point is a Cross Point.

 

 

 

 

 

 

No

 

This point is not a Cross Point.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do not use Cross points for Fire points.

The P## Cross Point option is designed to reduce false alarms. To achieve this, program two or more points within a Cross Point Group with this prompt enabled. The Cross point feature is available only on points where P## Pt Response is set to a value that generates an instant alarm response.

Bosch Security Systems, Inc. 10/08 F01U003636-04

Page 100
Image 100
Bosch Appliances D9412GV2 manual ## Report Bypass at Occurrence, ## Cross Point

D9412GV2 specifications

The Bosch D9412GV2 is an exceptional dishwasher that stands out in the competitive world of home appliances. Known for its reliability and advanced features, this model offers a blend of cutting-edge technology and user-friendly design that appeals to modern households.

One of the most noteworthy features of the D9412GV2 is its impressive cleaning performance. Boasting a unique combination of powerful jets and specialized wash cycles, it ensures that even the toughest stains are removed effectively. The dishwasher features Bosch’s patented PrecisionWash system, which utilizes intelligent sensors to monitor the wash cycle’s progress and adjust the water spray for optimal cleaning results. This not only guarantees sparkling dishes but also conserves water and energy.

In terms of capacity, the D9412GV2 does not disappoint. It has a spacious interior that is designed to accommodate up to 16 place settings, making it an ideal choice for families or those who frequently entertain guests. The adjustable racks and flexible loading options allow users to maximize space and customize the dishwasher to suit their unique needs. The third rack is particularly useful for utensils and smaller items, providing additional space that enhances efficiency.

The dishwasher is also engineered with noise reduction features for a quieter operation. With a sound rating of 44 decibels, it operates silently in the background, allowing for uninterrupted conversations and a peaceful home environment. This is especially beneficial for open-concept living spaces.

Energy efficiency is another hallmark of the Bosch D9412GV2. It is Energy Star certified, reflecting its commitment to sustainable practices. It uses less water and electricity without compromising performance, making it a responsible choice for eco-conscious consumers.

Moreover, the presence of the Home Connect feature allows users to control and monitor their dishwasher remotely via a smartphone app. This innovative technology enables users to start or stop cycles, receive notifications, and even download new wash programs, adding convenience and flexibility to busy lifestyles.

In conclusion, the Bosch D9412GV2 is a state-of-the-art dishwasher that excels in cleaning performance, capacity, and energy efficiency. With its innovative technologies and thoughtful design, it represents Bosch's commitment to quality and customer satisfaction, making it a valuable addition to any kitchen.