A# Perimeter O/C

D9412GV2/D7412GV2 Program Entry Guide 2.0 GV2MAIN

EN 47

A# Perimeter O/C

Default:

No

Selection:

Yes or No

Yes

This area can send Perimeter Opening and

 

Closing Reports.

 

 

No

This area cannot send Perimeter Opening

 

and Closing Reports.

 

 

 

This item determines if this area can send Perimeter Instant and Perimeter Delay Closing Reports and normal Opening Reports to the central station. Opening and Closing Windows do not suppress this event. Refer to the L## Perimeter O/C prompt on page 75

Needs modem format reporting. Some central station automation systems cannot process these reports.

A# Latest Close Time

Default: 00:00

Selection: 00:00 to 24:00

Use to set a Latest Close Time boundary value for this area. If the Latest Close Time value is non-zero, the time of day specified with the Extend Close feature cannot be greater than or equal to this value. A zero value for A# Latest Close Time disables the feature for the area.

Example: If A# Latest Close Time is set for 17:30, the user can extend the close time to as late as 17:29.

This prompt is used only when an O/C Window is assigned to an area. Make entries in 30-min increments using a 24-hour format. Use times that begin on the hour or the half-hour only. For example, enter 2:30 PM as 14:30. Enter 1:00 AM as 01:00. To set the Latest Close Time for midnight, use a value of 24:00. The latest close time allowed by the Extend Close feature is 24:58, because of internal limitations in the control panel.

The default entry of 00:00 disables the

Latest Close Time feature for this area.

The control panel sets all windows for the next day when the control panel clock turns to midnight. The control panel must cross the midnight boundary before any changes in that default setting occur.

To extend across midnight, you must use two windows:

To suppress reports before midnight, use one window (for example, 20:00 start to 23:59 stop).

To suppress reports immediately after midnight, use another window (for example, 00:01 start to 02:00 stop).

2.9.6Arming Features

A# Two Man Rule

 

Default:

 

No

 

 

Selection:

 

Yes or No

 

 

Yes

 

Two valid unique passcodes are

 

 

 

 

 

required to disarm the area.

 

 

 

 

 

 

 

No

A single passcode with a valid

 

 

 

 

 

authority level can disarm the area.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The D720 Keypad does not support the

Two-Man Rule feature.

Use this parameter when disarming an area that is Master Armed. After recognizing the first valid passcode, the system requests a second passcode to disarm the area. If the entry delay expires before the entry of a second valid unique passcode, an alarm condition occurs. This function works only when you use Passcode Disarm.

When you are disarming an area with A# Two Man Rule set to Yes, the keypad waits for the time equal to the A# Exit Delay Time. If the second passcode is not entered before the prompt times out, the rule resets and waits for the first passcode again.

If the area is already in an alarm condition, the first valid passcode entered after the alarm occurs silences the bell but does not disarm the area. Enter Code 2 appears on the display. A second valid unique passcode is necessary to disarm the area.

This feature is not allowed for use with SIA CP-01 compliant installations. Consult the local authority having jurisdiction (AHJ) for proper usage. Refer to your control panel’s program entry guide for programming information.