Bosch Appliances D9412GV2 manual 3.0RADXUSR1/RADXUSR2, 3.1Pass Code or Token Worksheet

Models: D9412GV2

1 158
Download 158 pages 17.38 Kb
Page 84
Image 84
3.0RADXUSR1/RADXUSR2

D9412GV2/D7412GV2 Program Entry Guide 3.0 RADXUSR1/RADXUSR2

EN 84

3.0RADXUSR1/RADXUSR2

3.1Pass Code or Token Worksheet

These programming items assign:

a pass code to user groups 001 to 249,

areas by authority level, and

a User Group Window.

Two handlers in the D5200 Programmer are used to program the users:

RADXUSR1 Handler programs users 000 to 124.

RADXUSR2 programs users 125 to 249 (D9412GV2 only).

3.1.1User Groups

For the D9412GV2, there are 249 groups (99 groups for the D7412GV2) consisting of one user with a pass code and token (master) and three users with tokens or cards but not a pass code (sub-user). All users in the group share the same authority level as the master user.

3.1.2Pass Codes

In a control panel with factory default settings, only the master user has an assigned pass code. A pass code can be three to six digits. Entering three digits in User ### chooses the user. Programming the U001 Passcode assigns a pass code to the master user. Sub-users cannot use the pass code. Do not assign tokens or cards to User ID 0 (zero), which is reserved for the service pass code.

Passcode Tamper

If a user enters six consecutive invalid pass codes at the same keypad, the control panel sends a User Code Tamper report to the cental station. The invalid pass code count resets when a valid passcode is entered at the same keypad. Refer to R# Usr Code Tamper in Table 11 on page 18 for information on enabling this report.

The passcode tamper condition is also reported in a manually initiated Extended Test Report and to RPS through control panel diagnostics. As a result, the tamper condition is reset after the successful completion of a manual report or when disconnecting from an RPS session. The tamper condition is not reset when the control panel reboots.

3.1.3User Group Window

Use U### User Group to enable and disable the U### Passcode for up to eight different time periods throughout the day. Assign the number (1 to 8) programmed in U### User Group to a User Windows #. If the user is outside a window, COMMAND DISABLED appears on the keypad after the user enters the pass code and presses [ENTER].

This window does not affect tokens and cards. It only affects the pass code of the master user.

When using the Add/Change User function at the keypad, the authority levels and the changes made affect the master user’s pass code and the entire group’s token or cards.

When using the ACCESS CTL LVL function at the keypad, the whole group is affected by whether or not the level is on or off for access control functions only.

When using the DELETE USER? function, the whole group is deleted. You cannot delete each user within the group individually. Use the ADD/CHG USER? function to change a user token or card instead of deleting the whole group.

3.1.4User Name

Each user group can be assigned one U### Name. This name is logged and sent to the central station for all the users in the group. The user ID is used to differentiate which user’s token or card was executed.

When using a D1260 Keypad, User 249 text is used for contact information text (such as telephone numbers). If a D1260 is installed on the system, do not use User 249 for user ID information.

3.1.5Tokens and Cards

The master user assigned the pass code can also be assigned a token or card by programming the U### Mstr Site and U### Mstr Crd Data.

Three more tokens or cards are assigned to the user group for sub-users using the U### SU# Site and U### SU# C/D.