RPS IP Address 1

D9412GV2/D7412GV2 Program Entry Guide 6.0 GV2AUX

EN 130

RPS IP Address 1

Default:

0

Selection:

0 to 255

0 to 255

Enter the first three digits of the IP

 

address. Leading zeros are not

 

required.

 

 

This prompt and the next three prompts determine the IP address for RPS.

An IP address has four fields. Each field has a range of 0 to 255. For example, an IP address is expressed as 110.227.64.190. (Refer to igure 7.) The D5200 programmer divides the IP Address into four programmable fields. Contact your network administrator to determine the IP address to which the RPS computer is connected.

igure 7: RPS IP Address Prompts

110.227.64.190

RPS IP Address 1

RPS IP Address 2

RPS IP Address 3

RPS IP Address 4

Set RPS IP Address to 0 if Enable Ext

Modem is set to Yes.

RPS IP Address 2

Default: 0

Selection: 0 to 255

Refer to RPS IP Address 1.

RPS IP Address 3

Default: 0

Selection: 0 to 255

Refer to RPS IP Address 1.

RPS IP Address 4

Default: 0

Selection: 0 to 255

Refer to RPS IP Address 1.

RPS Port Number

Default: 7700

Selection: 1 to 65535

This prompt specifies the destination port for outgoing RPS session requests to the IP address specified in RPS IP Address #.

6.4.2Using an External Modem

Through the use of a standard, off-the-shelf modem (capable of communicating at 9600 baud) and a D9133DC connected directly to the control panel, RPS can communicate with a D9412GV2 or D7412GV2 at speeds of up to 9600 baud.

Both the U.S.Robotics V.92 56 K Modem (model No. 5686, includes V.92 and V.90 56 K standard technology) and the Best Data Smart One V.92/V.44 56 K External Data/Fax Modem (model # 56SX-92) are recommended for use as external modems (connected to the control panel) based on compatibility testing by Bosch Security Systems, Inc. Other modules were not tested or were incompatible.

The seven prompts on page 134 help to configure the requirements necessary to connect an external modem to a D9412GV2 or D7412GV2 Control Panel using a D9133DC. This configuration allows communication with RPS at 9600 baud because data is routed through the SDI bus.

Use a separate phone line if an external modem is being connected to the control panel by a D9133DC Direct Connect Programming Module. If obtaining a different phone line from the line used by the control panel is impossible, ensure that the control panel is wired in front of any premises phone and the external modem devices so that full line seizure is maintained. Also, ensure that the following items are programmed in Section 2.7 RPS Parameters on page 32:

Answer Armed = Blank or 0

Answer Disarmed = Blank or 0

RPS Line Monitor = No

RPS Call Back = No

RPS Phone number = Blank