Bosch Appliances D9412GV2 manual L## Master Arm Delay, L## Mstr Arm Inst, L## Perim Delay

Models: D9412GV2

1 158
Download 158 pages 17.38 Kb
Page 68
Image 68
L## Master Arm Delay

D9412GV2/D7412GV2 Program Entry Guide 2.0 GV2MAIN

EN 68

L## Master Arm Delay

 

Default:

Refer to the program record sheet

 

Selection

Blank or E

 

 

:

 

 

 

 

 

 

 

Function

Function Name

Alternate

 

No.

 

Keystroke

 

2

Master Arm

[COMMAND][1]

 

 

Delay

 

Master arms areas based on the CC# Scope of the keypad using an exit delay time.

When this item is accessed through the Function List, Master Arm All allows the user to arm all areas according to the authority level of the user and within the CC# Scope of the keypad using an exit delay time.

Arm Area arms only the area displayed. If COMMAND 1 is used, it arms only the area where the keypad is assigned.

L## Mstr Arm Inst

Default:

Refer to the program record sheet

Selection:

Blank or E

 

 

 

 

Function

Function Name

Alternate

No.

 

Keystroke

3

Master Arm

[COMMAND][1][1]

 

Instant

 

This authority level permission allows a user to execute the Master Arm Inst function. Refer to Mstr Arm Inst on page61.

Arm Area arms only the area to which the keypad is assigned.

If COMMAND 11 is used, it arms only the area where the keypad is assigned.

Use COMMAND 11 carefully because all Perimeter and Interior points become Instant Armed.

L## Perim Delay

Default:

Refer to the program record sheet

Selection:

Blank or E

 

 

 

 

Function

Function Name

Alternate

No.

 

Keystroke

5

Perimeter Delay

[COMMAND][3]

 

Arm

 

Delay arm all Perimeter Delay point responses only in the area where the keypad is assigned.

L## Watch Mode

Default:

Refer to the program record sheet

Selection:

Blank or E

 

 

 

 

Function

Function Name

Alternate

No.

 

Keystroke

6

Watch Mode

[COMMAND][6]

Initiate the Watch Mode in the area to which this keypad is assigned.

L## Perim Partial

Default:

Refer to the program record sheet

Selection:

Blank or E

 

 

 

 

Function

Function Name

Alternate

No.

 

Keystroke

7

Perimeter Partial

[COMMAND][8]

 

Arm

 

Partially arms only the area where the keypad is assigned.

This function ignores the A# FA Bypass

Max entry in Area Parameters.

Local Only Reporting: No Closing Report is sent to the central station, but a Perimeter Delay Closing Event is generated in the event log.

L## Perim Instant

Default:

Refer to the program record sheet

Selection:

Blank or E

 

 

 

 

Function

Function Name

Alternate

No.

 

Keystroke

4

Perimeter Instant

[COMMAND][2]

 

Arm

 

Instant arm all Perimeter points, including Delayed points, only in the area where the keypad is assigned.

L## View Area Stat

 

Default:

 

 

Refer to the program record sheet

 

Selection:

 

 

Blank or E

 

 

 

 

 

 

 

 

Function

 

 

Function Name

Alternate

 

No.

 

 

 

Keystroke

 

8

 

 

View Area Status

(Menu function

 

 

 

 

 

only)

View the current arm or disarm status and the not ready to arm status of all areas within the scope of the keypad in this area. The user needs arming and disarming authority.

Bosch Security Systems, Inc. 10/08 F01U003636-04

Page 68
Image 68