D9412GV2/D7412GV2 Program Entry Guide 5.0 RADXSKED

EN 122

Default:

Blank

 

 

 

Selection:

1 to 11, 13 to 24, 28, 29

 

 

23

No Entry Events On: The

S## Door 1 [through 8]

Yes

Enable the sending

 

control panel can log No Entry

 

of No Entry Events

 

 

 

 

Events when an invalid token is

Default: No

 

for Door #.

 

detected for a specific door. No

Selection: Yes or No

No

Do not enable the

 

Entry Events include No Entry-

 

This parameter enables the sending

 

sending of No

 

Secured, No Entry-Interlock, No

 

 

Entry-Unknown ID, and No

of No Entry Events for Door #.

 

Entry Events for

 

Entry-Level. These events can

 

 

Door #.

 

 

 

 

 

be directed to print at a local

 

 

 

 

printer or send a report remotely

 

 

 

 

through phone routing. This

 

 

 

 

sked enables No Entry Events

 

 

 

 

to be reported for Door #.

 

 

 

 

 

 

 

 

24

No Entry Events Off: The

S## Door 1 [through 8]

Yes

Enable the

 

control panel can log No Entry

 

reporting of No

 

Default: No

 

 

Events when an invalid token is

 

Entry Events for

 

detected for a specific door. No

 

 

Door #.

 

Entry Events include No Entry-

Selection: Yes or No

No

Do not enable the

 

Secured, No Entry-Interlock, No

 

This parameter disables the sending

 

reporting of No

 

Entry-Unknown ID, and No

 

 

 

Entry Events for

 

Entry-Level. These events can

of No Entry Events for Door #.

 

 

 

Door #.

 

be directed to print at a local

 

 

 

 

 

 

 

printer or send a report remotely

 

 

 

 

through phone routing. This

 

 

 

 

sked disables No Entry Events

 

 

 

 

to be reported for Door #.

 

 

 

 

 

 

 

 

28

Expanded Off-Normal Test Report: To generate this event, one or more points must be in an off-

 

normal state at the time the sked executes. In addition, any system trouble that is active also

 

generates an Expanded Off-Normal Test Report. Expanded Off-Normal Test Reports include the Off

 

Normal Test Report Event as well as the supplementary event at the time the report is generated.

 

The Event Log shows only a Test Report Event.

 

 

 

If none of these conditions exists at the time the sked executes, only a Sked Executed Event is

 

generated and the Off-Normal Test Report is not sent.

 

 

29

Non-ExpandedOff-Normal Test Report: Non-Expanded Off-Normal Test Report Events are only

 

sent when any point is in the off-normal state from any area, but only sends the Off Normal Test

 

Report Event. Any system trouble that is active also generates a Non-Expanded Off-Normal Test

 

Report.

 

 

 

 

 

The Event Log only shows a Test Report Event.

 

 

 

If none of these conditions exist at the time the sked executes, only a Sked Executed Event is

 

generated and the Non-Expanded Off-Normal Test Report is not sent.

 

 

 

 

 

 

 

 

To meet UL 864 daily Test Report requirements (when using two phone lines), you must still use Sked Function Code 9, Test Report and program it to occur on a daily basis as per AHJ requirements.