Bosch Appliances D9412GV2 manual Add User, View Log, Del User, Extend Close, Print Log, User Cmd

Models: D9412GV2

1 158
Download 158 pages 17.38 Kb
Page 64
Image 64
Add User

 

D9412GV2/D7412GV2 Program Entry Guide 2.0

GV2MAIN

 

 

 

 

 

 

 

 

 

 

 

Add User

 

 

View Log

 

 

 

 

 

EN 64

Default:

P

 

Selection:

Blank, E, or P

 

 

 

 

Function

Function Name

Alternate

No.

 

Keystroke

18

Add User

[COMMAND][5][6]

Use this function to add or change pass codes, add or change tokens or cards and Sub-users, and add or change control panel authority levels (L##) by area.

Del User

Default:

P

 

Selection:

Blank, E, or P

 

 

 

 

Function

Function Name

Alternate

No.

 

Keystroke

19

Delete User

[COMMAND][5][3]

Default:

 

E

 

Selection:

 

Blank, E, or P

 

 

 

 

 

Function

 

Function Name

Alternate

No.

 

 

Keystroke

21

 

View Log

(Menu function

 

 

 

only)

Use this function to view all of the system events, their time stamps, User IDs, or point numbers. User Name and Point Text are not stored in the event log, but they appear when the control panel matches them with the User ID ### and the Point ###.

Each event appears on one line in the log. Any information related to that event appears on a separate line in the log.

Because events in the log are not uniform in length, the control panel can store from 500 to 1000 events.

Use this function to delete a user’s pass code and tokens or cards. It does not delete user names.

This function deletes the pass code, master user, and all sub-users associated with the user number.

Extend Close

Default:

P

 

Selection:

Blank, E, or P

 

 

 

 

Function

Function Name

Alternate

No.

 

Keystroke

20

Extend Close

[COMMAND][5][1]

Use this function to change the expected closing time for the area. The window cannot be adjusted until the Close Early Begin time passes and the Closing Window is active.

Print Log

Default:

P

 

Selection:

Blank, E, or P

 

 

 

 

Function

Function Name

Alternate

No.

 

Keystroke

22

Print Event Log

(Menu function

 

 

only)

Use this function to print all the events stored in the control panel beginning at the start date and ending with the last event in the log.

User Cmd 7

Default:

P

 

Selection:

Blank, E, or P

 

 

 

 

Function

Function Name

Alternate

No.

 

Keystroke

23

User COMMAND

[COMMAND][7]

 

7

 

Use this function to activate an alarm programmed in

COMMAND 7 in the RADXPNTS Handler.

Bosch Security Systems, Inc. 10/08 F01U003636-04

Page 64
Image 64
Bosch Appliances D9412GV2 manual Add User, View Log, Del User, Extend Close, Print Log, User Cmd, GV2MAIN