D9412GV2/D7412GV2 Program Entry Guide 2.0 GV2MAIN

EN 27

Table 21: Event Descriptions, Priorities, and Numbers

 

Event

 

 

Priorit

Event

Event Description

y

Number

Fire Alarm

001

011

Fire Restoral (after Alarm,

005

014

Supervision)

 

 

Fire Missing

005

013

Fire Trouble

005

012

Fire Supervision

005

124

Fire Restoral (after Tbl, Msg,

005

015

Bypass)

 

 

Fire Cancel

004

027

Fire Supervision Missing

005

146

Fire Supervision Restore

005

123

Alarm Report

003

016

Burg Restore

006

018

Duress

002

004

Missing Alarm

006

019

User Code Tamper

008

055

 

 

 

Trouble Report

006

017

Missing Trouble

008

020

Non-Fire Supervision

006

078

Point Bus Fail

006

024

Point Bus Restoral

006

091

Non-Fire Cancel

004

045

Alarm Restore

006

026

Supervision Missing

008

147

Unverified Event

006

169

Point Bypass/Command Bypass

007

007

 

 

 

Forced Point

007

008

Point Opening

008

021

Point Closing

008

022

Was Force Armed

007

034

Fail To Open

008

040

Fail To Close

008

041

Extend Close Time

008

044

Opening Report

008

047

Forced Close

007

048

Closing Report

008

050

 

 

 

Table 21: Event Descriptions, Priorities, and Numbers (Continued)

 

Event

Event

 

Priorit

Event Description

y

Number

Forced Close Perim Instant

007

084

Forced Close Perim Delay

007

085

 

 

 

Perimeter Instant Armed

008

088

Perimeter Delay Armed

008

089

Send User Text

n/a

n/a

S: Alarm

n/a

n/a

S: Trouble

n/a

n/a

S: Supervision

n/a

n/a

Status Report

008

035

S: Open

n/a

n/a

S: Close

n/a

n/a

Test Report

008

051

 

 

 

S: Perimeter Instant

n/a

n/a

S: Perimeter Delay

n/a

n/a

S: Fire Supervision

n/a

n/a

S: Fire Alarm

n/a

n/a

S: Fire Trouble

n/a

n/a

S: Missing Fire (Trouble)

n/a

n/a

S: Missing Burglary ((Trouble)

n/a

n/a

S: Missing Burglary (Alarm)

n/a

n/a

S: Fire Supervision Missing

n/a

n/a

S: Burglary Supervision Missing

n/a

n/a

 

 

 

S: Door Left Open

n/a

n/a

SDI Device Failure*

004

070

SDI Device Restoral*

008

071

Watchdog Reset

004

077

Parameter Checksum Fail

n/a

n/a

Reboot

008

082

Phone Line Fail

004

068

Phone Line Restoral

008

069

AC Failure

004

072

AC Restoral

008

073

 

 

 

Battery Missing

004

074

Battery Low

004

075

Battery Restoral

008

076

Route Comm Fail

004

066

Route Comm Restore

008

067

Checksum Fail

n/a

n/a

Sensor Reset

007

031

Relay Set

007

032

Relay Reset

007

033

Sked Executed

007

057

Sked Changed

007

058

Fail to Execute

008

151

Event Log Threshold

008

052

Event Log Overflow

008

053

*SDI Device number is not reported when using pager format.