L## Security Level

D9412GV2/D7412GV2 Program Entry Guide 2.0 GV2MAIN

EN 76

2.11.5 Access Control Levels

L## Security Level

Default:

Refer to the program record sheet

Selection:

M, P, D, or Blank

M

Users have access rights for this

 

area when the area is in any armed

 

state.

 

 

P

Users have access rights for this

 

area when the area is Perimeter

 

Armed or Disarmed but not while the

 

area is Master Armed.

 

 

D

Users have access rights for this

 

area only while it is disarmed.

 

 

Blank

Users do not have access rights to

 

this area.

 

 

Security Level [TOKEN FUNCTION]

When the user presents a token or card at the reader, access is granted only when the user has the authority to enter the area under certain armed conditions.

L## Disarm Level

Default:

Refer to the program record sheet

Selection:

I, D, or Blank

I

Users change the Master Armed

 

state and Perimeter Armed state to

 

Perimeter Instant. The armed state

 

does not change in other areas, and

 

the armed state does not change if

 

the area is already in the perimeter

 

instant or disarmed state. User

 

needs access level for Master

 

Armed (M) state.

 

 

D

Users change the local area’s

 

Master Armed state and Perimeter

 

Armed state to the Disarm state.

 

User needs access level for Master

 

Armed (M) or Perimeter Armed (P)

 

state. All areas within the scope of

 

the keypad assigned to the D# CC#

 

Scope in the access handler, and

 

areas to which the user has disarm

 

rights, disarm as programmed.

 

 

Blank

Users do not have disarm rights in

 

this area.

 

 

Burglar bells are silenced in the local area when a user disarms with a token or card or presents the token or card during an alarm. The user must use a pass code to silence a Fire Bell. Cancel Reports are sent after a valid pass code or token or card silences the bell.

Opening and Closing Reports are sent to the central station receiver if programmed.

For more information on programming this prompt for a shared area, refer to Access Control Readers Assigned to the Shared Area in Section 2.9.3 Shared- Area Characteristics on page 41.

L## Function Level

Default:

Refer to the program record sheet

Selection:

M, D, C, or Blank

 

 

MActivate the custom function assigned to the door in this area while the area is Master Armed or Disarmed only.

 

D

Activate the custom function

 

 

 

assigned to the door in this area

 

 

 

while the area is Disarmed only.

 

 

 

 

 

C

User can activate the custom

 

 

 

function assigned to the door in this

 

 

 

area while the area is Master Armed,

 

 

 

Perimeter Armed or Disarmed.

 

 

 

 

 

Blank

User cannot activate the custom

 

 

 

function assigned to the door in this

 

 

 

area.

 

 

 

 

 

 

 

 

 

 

 

When a token or card can also disarm an

 

 

 

 

 

 

 

 

 

area, the custom function starts after the

 

 

 

area disarms.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A user does not require L## Security

 

 

 

 

 

 

 

 

 

Level or L## Disarm Level authority to

 

 

 

activate a custom function with a token or

 

 

 

 

 

 

card.

 

 

 

 

 

 

 

Tokens or cards that are used to execute

 

 

 

 

 

 

 

 

 

Custom Functions must have a pass

 

 

 

code assigned to the correspoinding

 

 

 

 

 

 

User###.

 

 

 

 