Bosch Appliances D9412GV2 S## Cmd Center, Cmd Center and Custom Func, S## Custom Func, Default

Models: D9412GV2

1 158
Download 158 pages 17.38 Kb
Page 119
Image 119
S## Cmd Center

D9412GV2/D7412GV2 Program Entry Guide 5.0 RADXSKED

EN 119

Default:

Blank

 

 

 

Selection:

1 to 11, 13 to 24, 28, 29

 

 

 

11

Execute Custom Func: This

S## Cmd Center

Blank

No keypad is

 

function emulates any of the custom

(0)

specified for

 

 

 

functions assigned to the keypad

Default: Blank (0)

 

Custom Function

 

that can be executed by a user from

Selections: Blank (0), 1 to 8

 

activation.

 

the keypad. When a sked executes

 

 

 

Identify the specific keypad

1 to 8

Command center

 

a custom function, it is subject to

 

the scope of the selected keypad.

(CC #) where the Custom

 

(keypad) address

 

Cmd Center and Custom Func

Function is entered. Only one

 

specified for

 

prompts appear after entering

keypad can be assigned for

 

Custom Function

 

Function Code 11. Both entries are

this sked function.

 

activation.

 

required.

 

 

 

 

S## Custom Func

Blank

No Custom

 

 

 

 

 

 

(0)

Function is

 

 

 

 

 

 

 

Default: Blank (0)

 

activated.

 

 

 

Selections: Blank (0),

128 to

Custom Function

 

 

 

128 to 143 for D9412GV2,

143

to activate.

 

 

 

128 to 131 for D7412GV2

 

 

 

 

 

Enter the custom function this

 

 

 

 

 

sked executes.

 

 

 

 

 

 

 

 

Avoid having multiple functions occur at the same time at the same address. Functions can clash and the effect on the control panel is unpredictable.

Ensure that the Custom Function being executed or any of the commands nested inside the Custom Function are not pass-code protected.

Do not program multiple skeds to execute at the same keypad during the same time.

Do not program skeds to execute at times when a user is likely to be executing functions at the keypad. If it is necessary to do so, there are two ways to work around the situation:

1.Program CC at the beginning of the Custom Function Key Strokes entry. This aborts the user’s function and allows the sked to execute.

2.Program the sked to execute at an address (Cmd Center) with no keypad physically attached to it. The CC # must be assigned to an area and have the appropriate scope programmed.

Default: Blank

Selection: 1 to 11, 13 to 24, 28, 29

13Adjust Time Forward One Hour: This sked function is used to make adjustments to the control panel’s clock. A typical application is to program this to go into effect at 2:00 AM on the date that Daylight Saving Time begins (during the springtime). No Time Change Report is sent or logged, but the new time appears in the next report logged.

No other parameters require input for this option.

14Adjust Time Backward One Hour: This sked function is used to make adjustments to the control panel’s clock. A typical application is to program this to go into effect at 2:00 AM on the date that Daylight Saving Time ends (during the fall). This function can operate only once in a day, even if multiple Skeds with this function are programmed. No Time Change Report is sent or logged, but the new time appears in the next report logged.

There are no other parameters that require input for this option.