To disable the window, both the hours and minutes spaces must be blank.

00:00 is midnight, 23:59 is 11:59 PM. Make entries using a 24-hour clock (for example, 7:00 AM is entered as 07:00, 2:45 PM is entered as 14:45).

If the window must activate on the same day as it is programmed, reboot the control panel to activate the window immediately.

W# Close Window Start

Default:

00: 00

Selection:

HH:MM (hours and minutes)

 

 

Enter the time that you want the control panel to start the Closing Window. The window goes into effect at the beginning of the minute.

00:00 is midnight, 23:59 is 11:59 PM. Make entries using a 24-hour clock (for example, 7:00 AM is entered as 07:00, 2:45 PM is entered as 14:45).

This program item is one of three required to create a Closing Window. To program a Closing Window, Close Early Begin and Close Window Stop must also be programmed.

If the area is not armed when the Close Window Start time comes, a warning tone sounds and PLEASE CLOSE NOW appears at the keypad. To temporarily silence the tone, press the [ESC] key on the keypad. The warning tone restarts in 10 min if the area is not armed.

Refer to the W# Close Early Begin prompt in this section for explanations of report features.

W# Close Window Stop

Default:

 

00: 00

Selection:

 

HH:MM (hours and minutes)

 

 

 

Enter the time that you want the control panel to end the Closing Window. The window stops at the end of the minute.

00:00 is midnight, 23:59 is 11:59 PM. Make entries using a 24-hour clock (for example, 7:00 AM is entered as 07:00, 2:45 PM is entered as 14:45).

This program item is one of three required to create a Closing Window. To program a Closing Window, Close Early Begin and Close Window Start must also be programmed.

If the area is not armed by the time the Close Window Stop time expires, the control panel generates a Fail to Close Report if enabled in Fail To Close.

Closing Reports generated between the Close Window Start time and Close Window Stop time can be suppressed by programming Disable O/C in Window as Yes. Refer to the W# Close Early Begin prompt for other explanations of report features.

Do not use a time of 23:59 as a window stop time unless the window continues on the next day at 00:00. Fail to Close Reports are not sent, and the Auto Close feature does not work for windows that stop at 23:59.

Do not program a single window to cross the midnight boundary. The window stop time must be later than the window start time. To program a window that effectively crosses the midnight boundary, you must program two windows.

For example, to program windows for an area that closes between 11:30 PM and 12:30 AM, five days a week, use two windows as shown in Table 37.

Table 37: Programming Example: Linking Two Closing Windows over Midnight

W#

1

2

Day of Week

S M T W T F S

S M T W T F S

Open

Close

Early

 

Star

 

Sto

 

Early

 

 

 

 

Begi

 

 

 

 

Start

 

Stop

n

 

t

 

p

 

Begin

 

 

 

 

 

 

 

 

22 : 00

 

23 : 30

 

23 : 59

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00 : 00

00 : 00

00 : 30

 

 

 

 

 

 

 

 

 

 

 

eXcept

On

Holiday

Yes No

Yes No

Holiday

Index

1 2 3 4

1 2 3 4

Area(s)

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

Bosch Security Systems, Inc. 10/08 F01U003636-04

Page 110
Image 110
Bosch Appliances D9412GV2 manual W# Close Window Start, W# Close Window Stop, Default, Selection, HH:MM hours and minutes