CC# Scroll Lock

D9412GV2/D7412GV2 Program Entry Guide 2.0 GV2MAIN

EN 56

CC# Scroll Lock

Default:

No

Selection:

Yes or No

Yes

Prevents the idle system status text

 

from scrolling automatically.

 

Requires user intervention to

 

advance.

 

 

No

Allows the idle system status text to

 

scroll automatically without user

 

intervention

 

 

Use this parameter to enable a special non-scrolling option for the idle system status display text on a keypad. This keypad mode requires the user to press the PREV or NEXT key on the keypad to unlock the display and begin scrolling through the system status displays.

CC# Menu Key Lock

Default:

No

Selection:

Yes or No

Yes

If set to Yes, the user is prompted to

 

enter a pass code after pressing the

 

Menu key on the keypad. The items

 

programmed in the Menu List for this

 

specific keypad are filtered by the

 

user’s authority level. Only those

 

items in the menu list for which the

 

user has authority appear.

 

 

No

If set to No, when the user presses

 

the Menu key, all items that are

 

programmed in the Menu List for the

 

Command Center Address (Keypad

 

Address) appear, regardless of the

 

user’s authority level.

 

 

Determines if the Menu Key, when pressed, requires a pass code to access the functions.

If this parameter is set to Yes, users must enter a pass code after pressing the Menu key. When the pass code is validated, only those functions for which the user has authority appear in the list. If a function in the Menu List is pass-code protected (refer to Keypad Functions in Section 2.11.2 User Interface on page) the user does not need to enter the pass code again.

CC# Abort Display

Default:

 

Yes

Selection:

 

Yes or No

Yes

 

This keypad shows the Alarm

 

 

Aborted message for all aborted

 

 

alarms within its scope.

 

 

 

No

 

This keypad does not show the

 

 

Alarm Aborted message for all

 

 

aborted alarms within its scope.

 

 

 

This parameter enables or disables the ALARM NOT SENT message when an alarm is aborted before transmission occurs.

For SIA CP-01 Compliance

CC# Abort Display can be set to Yes or No.

CC# Cancel Display

Default:

 

Yes

 

 

 

Selection:

 

Yes or No

Yes

 

This keypad shows the Cancel

 

 

Report Sent message for all canceled

 

 

alarms within its scope.

 

 

 

No

 

This keypad does not show the

 

 

Cancel Report Sent message for all

 

 

canceled alarms within its scope.

 

 

 

This parameter enables or disables the CANCEL RPT SENT display message when an alarm is canceled after transmission occurs. To show this message, Cancel Report must be set to Yes. Refer to Cancel Report on page 36.

For SIA CP-01 Compliance

CC# Cancel Display can be set to Yes or No.