Actiontec electronic 56K V.90 manual Can’t Connect at 56K

Page 37

Can’t Connect at 56K

Note: Current FCC regulations limit your maximum connection rate to 53Kbits / s.

The number you are calling may not support V.90 or K56flex protocols. Some ISPs (Internet Service Provider) have special numbers that you must call to connect to 56K. Contact your service provider and ask if the number you are calling supports V.90 or K56flex connections to their service.

Check the maximum speed setting in the Modem Properties window. On the task- bar, click Start. On the Start menu, click Settings, then click Control Panels. Double- click the Modems icon. Highlight your modem by clicking once on the icon next to the modem and then click the Properties button. Select the General tab and look at the setting in the Maximum speed box. Make sure this is set to 115200.

You may have other telephone devices connected to the phone line. To help your modem achieve the best connection possible, remove all extra devices and their cables from the telephone line when the modem is in use. This reduces the load on your phone line and keeps signal attenuation to a minimum.

Keep the length of your phone line cable to 10 feet or less. Don’t use an unusually long cable to connect to the phone line socket. If necessary, move the computer closer to the phone socket. Don’t lay your cabling close to an electrical appliance like a refrigerator or air conditioner unit. High current devices can transmit a 60 cycle “hum” to your modem through the phone cord. This may cause frequent renegotia- tions or line disconnects while the appliance is running.

The telephone line conditions at the time of your call may not let you connect at 56K. The modem has a connection sequence of K56flex, then V.90, then V.34, and so on. The modem attempts to make the highest connect rate that your telephone line can support at the time of negotiation. If the line conditions (noise, telephone company routing, etc.) won’t allow a high data rate connection, then the modem will automatically connect at the most reliable rate. Try making the call again after a few minutes. The routing of the call may improve your chances of making a 56K connec- tion.

If you are attempting to make a call from an office, are you using a direct outside line or are you using a PBX hookup? If you have to dial “9” to reach an outside number, you are using a PBX. The modem cannot connect faster then V.34 if you are using a PBX. Try using the line that is connected to a fax machine. Fax machines are usually connected to a dedicated line and not through the PBX.

Your phone line may not support a 56K connection. Or may support a 56K connec- tion only intermittently. There are many conditions that must be met before a 56K

36

Image 37
Contents 56K V.90 PCI Voice/Fax Windows Modem Table of Contents Introduction Do This First For Windows 95 and Windows 98 InstallationsFor Windows NT 4.0 Installation For Windows 2000 Professional Installation Hardware Installation Installing The ModemInstalling The Modem Connecting Devices Connecting Devices to the ModemConfiguring Windows Page Configuring Windows 95B Page Configuring Windows Page Next Page Page Configuring Windows NT Page Page Page Configuring Windows 2000 Professional Page Page Page Page Confirming the Installation of the Driver in Windows Page Modem’s Voice Features Installing Communications SoftwarePage Windows 95/95B/98 TroubleshootingMore Info Panel Does Not Install Windows NT No Dialtone Error Common ProblemsCan’t Connect at 56K Uninstalling in Windows 95 Uninstalling the ModemLtcom.vxd ltwave.inf Page Repeat Last Command AT CommandsAnswer Command ATXnCarrier Control DnDial Echo CommandHook Control Online Data Character Echo CommandRequest ID Information Monitor Speaker VolumeModulation Handshake This command turns the speaker on or offSelect Pulse Dialing Return On-line to Data ModeResult Code Control Result Code Option DCE Response FormatDial Tone Detect Extended Result CodesLong Space Disconnect Busy Tone DetectRecall Stored Profile Data Carrier Detect DCD Control Auto RetrainDTR Control Load Factory Settings22bis Guard Tone Control Auxiliary Relay option Asynchronous Communications ModeLocal Flow Control Selection This Command is effective only for use in Japan Data Set Ready DSR Option View Active Configuration and Stored ProfileLSD Zn=x Store Telephone Number \Bn \AnModem Port Flow Control \Kn Same as 4.Default \Nn \Vn Protocol Result Code \Tn Inactivity TimerData Calling Tone \Xn XON/XOFF Pass ThroughV90=x Downstream Rate and Control AT Commands for Testing and Debugging Enable/Disable Data CompressionWrite to/Read from DSP Register Line-to-Line LoopbackATI11 XXX Type Registers ReferenceAscii Comma Dial Modifier Time Connection Completion Time-OutS10 S11 Dtmf Dialing SpeedS21 S14 General Bit Mapped Options StatusS22 S28 Modulation Enable/Disable S24 Timer to Control Sleep ModeS30 Inactivity Timer S32S35 Data Calling Tone S37 Dial Line Rate defaultS36 S42 Auto Rate default 1, range S38 56K Dial Line Rate defaultS43 Auto Mode default 1, range S90 S89 Timer to Control Sleep ModeS91 No Carrier S92Result Code FCC Part 68 Requirements FCC RegulationsDeclaration of Conformity Canadian Department Of Communications Cdoc