Missing or corrupted tape-backup software or tape drive device driver

Defective SCSI controller

Action

1Remove the tape cartridge you were using when the problem occurred, and replace it with a tape cartridge that you know works.

2Ensure that the SCSI device drivers for the tape drive are installed and are configured correctly.

3Reinstall the tape-backup software as instructed in the tape-backup software documentation.

4Ensure that the tape drive’s interface/DC power cable is connected to the tape drive and SCSI controller card.

5Verify that the tape drive is configured for a unique SCSI ID number and that the tape drive is terminated or not terminated, based on the interface cable used to connect the drive.

See the documentation for the tape drive for instructions on selecting the SCSI ID number and enabling or disabling termination.

6Run the appropriate online diagnostics tests. See "Using Server Administrator Diagnostics" on page 121.

7Open or remove the bezel. See "Removing the Bezel" on page 46.

8Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

9Open the system. See "Opening the System" on page 48.

10Ensure that the SCSI controller card is firmly seated in its connector. See "Installing an Expansion Card" on page 57.

11Close the system. See "Closing the System" on page 48.

12Reconnect the system to the electrical outlet, and turn on the system, including attached peripherals.

13If the problem is not resolved, see the documentation for the tape drive for additional troubleshooting instructions.

14If you cannot resolve the problem, see "Getting Help" on page 131 for information on obtaining technical assistance.

114

Troubleshooting Your System

Image 114
Contents Dell PowerEdge 1900 Systems W . d e l l . c o m s u p p o r t . d e l l . c o mMarch Contents Baseboard Management Controller Configuration Removing and Installing the Cooling Shroud FanControl Panel Assembly Service-Only Procedure Installing the Diskette Drive Into the Drive CarrierGeneral Memory Module Installation Guidelines Installing the Control Panel Assembly Contents101 Troubleshooting System Cooling Problems 109Troubleshooting an External Scsi Tape Drive 113 102117 Using Server Administrator Diagnostics 121Returning Items for Warranty Repair or Credit 133 Contents 118134 136Other Information You May Need About Your SystemAccessing System Features During Startup Front-Panel Features and Indicators Hard drives are in useButton Is on Immediately after the power button is pressedBe pressed using the end of a paper clip To the systemFront-Panel Components Icon Description USB connectors Back-Panel Features and Indicators OptionalNIC Indicator Codes Connecting External DevicesSupport E1114 Temp Ambient LCD Status MessagesE1000 FAILSAFE, Call E1116 Temp MemoryE12nn XX PwrGd E122C CPU Power FaultE1211 Romb Batt E1229E141C CPU Mismatch E1414 CPU # ThermtripE1418 CPU # Presence E141F CPU ProtocolE1711 E161C PS # Input LostE1710 Channel Chk PCI Perr Slot #E2017 Timer Fail E2011 Mem Config ErrE2013 Shadow Bios Fail E2018 Prog TimerE2111 SBE Log Disable E201F Drac ConfigE2020 CPU Config E2021 MemorySolving Problems Described by LCD Status Messages Fully Buffered Dimm FBDSystem Messages Removing LCD Status MessagesFailed Bios Update AttemptIs installed on system Board CPUs with different cacheDiskette drive n seek Diskette subsystem resetError Remote Access FailureGate A20 failure Configuration, ResourceManufacturing mode General failureNo timer tick interrupt No boot device availableNo boot sector on hard drive Northbound merge errorError PCI Bios failed to installPlug & Play Configuration Read fault Requested sector not foundUpdate loaded for Please run Setup programTimer chip counter Amount of systemDiagnostics Messages Write fault Write fault on selected driveFirmware is not present Alert Messages About Your System Entering the System Setup Program Responding to Error MessagesUsing the System Setup Program System Setup Options Using the System Setup ProgramMain Screen Main System Setup Program Screen Boot Sequence System Setup Program Options Description Memory InformationApplications when enabled. Disabled is the default Auto defaultCPU Information Screens Integrated Devices Screen Serial Communication ScreenSystem Security Screen System and Setup Password Features Exit ScreenUsing the System Password Using the System Setup Program Using the Setup Password Entering the BMC Setup Module Disabling a Forgotten PasswordBaseboard Management Controller Configuration BMC Setup Module OptionsInstalling System Components Recommended ToolsOpening and Closing the System Removing the BezelInstalling the Bezel Opening the System Closing the SystemCover latch Installing System Components Power Supply Removing the Power SupplyInstalling the Power Supply Cable retention clipsFans Removing and Installing a Fan Processor fan FAN2 Processor fan FAN3Removing and Installing the Cooling Shroud Fan Fan connector on system boardFan bracket latch Installing System Components Removing and Replacing the Cooling Shroud FanExpansion Cards Shows the relative locations of these expansion-card slotsInstalling an Expansion Card Card-edge guide Installing System ComponentsRemoving an Expansion Card Hard Drives Removing a Hard DriveInterface cable Installing a Hard Drive 11. Removing and Installing a Hard Drive Drive bay ScrewsSataa connector Satab connector Installing System Components Installing System Components Board connector Hard drive activity system SAS1 connectorInstalling System Components SAS x connector Board connector Card battery connectorInternal Tape Backup Unit Removing an Internal Scsi Tape Backup UnitInstalling an Internal Scsi Tape Backup Unit Power cablePeripheral bay Installing System Components Optical Drive Removing an Optical DriveInstalling an Optical Drive Diskette Drive Removing the Diskette DriveDiskette drive power cable Installing the Diskette Drive Into the Drive Carrier Installing the Diskette DriveSystem Battery Replacing the System BatteryNegative side of connector Cooling Shroud Removing the Cooling ShroudCenter fan bracket Chassis slot Installing System Components LatchRemoving the Center Fan Bracket Installing the Cooling ShroudFan Brackets Replacing the Center Fan BracketMemory Removing the Back Fan BracketReplacing the Back Fan Bracket 20. Dimm Sockets Installing System Components General Memory Module Installation Guidelines Non-Optimal Memory ConfigurationsMemory Sparing Support Installing Memory Modules Memory Mirroring SupportInstalling System Components Installing a RAC Card Removing Memory ModulesNotch in card edge Activating the Integrated NIC TOE MicroprocessorReplacing a Processor 23. Installing and Removing the Heat Sink Heat sink Socket-release lever Processor shield Installing System Components Replacing the SAS RAID Controller Daughter Card Battery SAS RAID Controller Daughter CardCable Expansion-bay bracket Battery bay RAID battery Card ConnectorRemoving the SAS RAID Controller Daughter Card SAS RAID controller daughter RAID battery cable SAS RAID Installing the SAS RAID Controller Daughter Card Configuring the Boot DriveControl Panel Assembly Service-Only Procedure Removing the Control Panel AssemblyDisplay module label Installing System Components System chassis Display module cableSystem Board Service-Only Procedure Installing the Control Panel AssemblyRemoving the System Board Page Installing the System Board Retention pinInstalling System Components Safety First-For You and Your System Start-Up Routine101 Checking the Equipment Troubleshooting IRQ Assignment ConflictsTroubleshooting External Connections 102Monitor is not working properly Video memory is faulty Troubleshooting the Video SubsystemTroubleshooting the Keyboard ProblemTroubleshooting Basic I/O Functions Troubleshooting the MouseTroubleshooting a Serial I/O Device Troubleshooting a USB Device105 NIC cannot communicate with network Troubleshooting a NICTroubleshooting a Wet System Liquid spilled on the system Excessive humidityTroubleshooting a Damaged System System was dropped or damaged107 Troubleshooting the System Battery Troubleshooting the Power SupplyTroubleshooting System Cooling Problems Troubleshooting a Fan109 Troubleshooting System Memory 111 Troubleshooting a Diskette Drive Error message indicates a diskette drive problemDefective tape drive Defective tape cartridge Troubleshooting an Optical DriveTroubleshooting an External Scsi Tape Drive 113Action Troubleshooting a Hard Drive 115116 Troubleshooting Expansion Cards 117Troubleshooting the Microprocessors 119 120 When to Use the System Diagnostics Using Server Administrator DiagnosticsSystem Diagnostics Features 121Using the Custom Test Options Running the System DiagnosticsSystem Diagnostics Testing Options Selecting Devices for TestingSelecting Diagnostics Options Viewing Information and Results123 124 Jumpers and Connectors System Board Jumpers125 System boot BootConfiguration settings in Nvram are cleared at next 126System Board Connectors 127128 129 130 131 Online ServicesTechnical Assistance Getting HelpTechnical Support Service AutoTech ServiceAutomated Order-Status Service Electronic Quote Service133 Before You Call 134135 Contacting Dell 136137 138 139 140 General Support 01-899-753-0777141 142 143 144 General Support dial from within Jamaica only145 146 147 General Support 001-800-882-1519General Support 001-800-220-1006 Getting Help General Support 0800-50-669 148General Support 001-800-507-0962 Fax 21 424 01149 150 151 152 153 154 Country Code Toll-Free Numbers City CodeGeneral Support 8001-3605 BTU British thermal unit 155Amperes AC Alternating current Celsius156 Cm Centimeters Cmos Complementary metal-oxide semiconductorFBD Fully buffered Dimm 157Fahrenheit Kilo Kb Kilobits 1024 bits Glossary158 LVD Low voltage differential Meters MA Milliamperes159 Romb RAID on motherboard GlossarySystem diskette See bootable diskette 160TCP/IP Transmission Control Protocol/Internet Protocol 161 Volts VAC Volts alternating current VDC Volts direct current162 163 IndexIndex 165 Status messages LCDIndex