Table
Code | Text | Causes | Corrective Actions |
|
|
|
|
E1211 | ROMB Batt | RAID battery is either missing, | Reseat the RAID battery. See |
|
| bad, or unable to recharge due to | "Replacing the SAS RAID |
|
| thermal issues. | Controller Daughter Card |
|
|
| Battery" on page 92, and |
|
|
| "Troubleshooting System Cooling |
|
|
| Problems" on page 109. |
|
|
|
|
E12nn | XX PwrGd | Specified voltage regulator has | See "Getting Help" on page 131. |
|
| failed. |
|
|
|
|
|
E1229 | CPU # VCORE | Processor # VCORE voltage | See "Getting Help" on page 131. |
|
| regulator has failed. |
|
|
|
|
|
E122B | 0.9V Over | 0.9 V regulator voltage has | See "Getting Help" on page 131. |
| Voltage | exceeded the allowable voltage |
|
|
| range |
|
|
|
|
|
E122C | CPU Power Fault | A voltage regulator failure was | See "Getting Help" on page 131. |
|
| detected when the processor |
|
|
| regulator(s) was enabled |
|
|
|
|
|
E1310 | RPM Fan ## | RPM of specified cooling fan is | See "Troubleshooting System |
|
| out of acceptable operating range. Cooling Problems" on page 109. | |
|
|
|
|
E1410 | CPU # IERR | Specified microprocessor is | See your system’s Information |
|
| reporting a system error. | Update Tech Sheet located on |
|
|
| support.dell.com for the most |
current system information. If the problem persists, see "Getting Help" on page 131.
About Your System
17