PSC SP400rf manual ~ 7E Del, Ascii Character SET

Page 39

ASCII CHARACTER SET

The table on this page shows a set of ASCII characters and their correspond- ing Hex Values. The Hex Values in this table are needed for setting symbol- ogy specific label identifiers, as well as enabling custom prefix and suffix characters.

ASCII

HEX

CHAR. VALUE

nul

00

soh

01

stx

02

etx

03

eot

04

enq

05

ack

06

bel

07

bs

08

ht

09

lf

0A

vt

0B

ff0C

cr 0D

so

0E

si

0F

dle

10

dc1

11

dc2

12

dc3

13

dc4

14

nak

15

syn

16

etb

17

can

18

em

19

sub

1A

esc

1B

fs

1C

gs

1D

rs

1E

us

1F

ASCII

HEX

CHAR. VALUE

sp

20

!

21

"

22

#

23

$

24

%25

&26

'27

(

28

)

29

*2A

+2B

'2C

-2D

.

2E

/2F

030

131

232

333

434

535

636

737

838

939

:3A

;3B

<3C

=3D

>3E

? 3F

ASCII HEX

CHAR. VALUE

@40

A41

B42

C43

D44

E45

F46

G47

H48

I

49

J4A

K4B

L

4C

M

4D

N4E

O4F

P50

Q51

R52

S53

T54

U55

V56

W 57

X58

Y59

Z5A

[

5B

\5C

]

5D

^5E

_ 5F

ASCII HEX

CHAR. VALUE

`60

a61

b62

c63

d64

e65

f

66

g67

h68

i69

j6A

k

6B

l

6C

m

6D

n6E

o6F

p70

q71

r72

s73

t

74

u75

v76

w

77

x78

y79

z7A

{7B

7C

}7D

~ 7E

del

7F

RANSMIT

CONFIG

LABEL T

FORMAT

R44-1027

33

Image 39
Contents Handheld Laser Scanner Disclaimer PSC Scanning, IncContents RS-232 Iii SP400RF Programming Guide Integrating Peripherals with Host Systems Need to Understand the BasicsSP400RF Interface Groups Changing InterfacesCustomizing Your Scanner Operation What is Programming MODE? HOW to Program Using BarcodesProgramming Overview Programming Session Scanner Response When in Programming ModeEND Return to Factory SettingsConfiguration Upload SETWhere to GO from Here IBM 4683/84 4693/94 Port 5B Interface SELECTION1 IBM 4683/84 4693/94 Port 5B SettingsSET Send AS Code IBM 4683/84 4693/94 Port 9A, 9B, 9C, 9E SettingsIBM 4682/92 Port E Interface Selection IBM 4682/92 Port E SettingsPSC1 Ocia Interface Selection NCR Ocia Nine BIT Long Format Interface SelectionSNI Ocia Interface Selection Nable Isable SETNable IsableWand Emulation Interface Selection Full AsciiEND LOWHigh C128Communication Parameter RS-232 Interface SelectionSNI RS-232 Interface Selection Data Bits Start Bit Parity Bits Stop Bits Data Format Settings Hardware Control Software Control SET = N ONE = 90 Milliseconds = 100 Milliseconds Type PC Keyboard Wedge Interface SelectionEyboard Wedge Interface Intercharacter Delay = 55 Milliseconds STI Keyboard Wedge Interface Selection Ibmxxxx STI WedgeLabel Transmit Format Configuration Items RS-232AND Keyboard Wedge Interfaces onlyPrefix & Suffix Label Transmit Format Config For the example in step four, scan 0, 2, 2 SET SET PrefixFor the example in step five, scan 0, 7, 0 SET SET SuffixSetting a Single Character Prefix or Suffix ONE Character only Ascii Character SET ~ 7E DelUPC-A Our example, we would scan the UPC-A symbology label EAN-13 UPC-AUPC-E EAN-8Code Codabar Interleaved 2 Standard 2 MSI/PLESSEY Scan the barcodes values Disabling Label I.D. for a Specific Symbology Label Transmit Format Config Interface Type UPC/EANCode Symbology Options Overview Enable UPC/EAN Disable UPC/EAN Enable Code Disable Code Symbology SelectionEnable MSI/PLESSEY Disable MSI/PLESSEY Enable Codabar Disable Codabar Enable Code Disable CodeUPC/EAN Options UPC/EAN Expansion Disabled END OptionalRequired UPC-E Sendcheck DigitSend Check Digit SET EAN-8PRICE/WEIGHT Check Digit Code 39 Options Ascii Scan the Set Code 39 Minimum Label Length barcode Code 39 Minimum Label Length Interleaved 2 Compute EnableDisable SET Dont ComputeScan the Enable First Fixed barcode SET Fixed Engths Standard 2 Normal or Iata Selection Iata Standard 2Dont Compute Dont Transmit Enable Disable Scan the Enable First Fixed barcode Standard 2 of 5 Fixed and Minimum Label Lengths Codabar Options Codabar Check Digit & Variable Length TRANSMIT1 Format = abcd/tn*eCodabar START/STOP Character SET Codabar Fixed LengthScan the Set Second Fixed Length label ONE Check Digit TWO Check DigitsMSI/PLESSEY Check Digit MSI/PLESSEY Fixed Length MSI/PLESSEY SET Fixed Lengths Code 128 Options General Features Communications Protocol General FeaturesEND Enable DisableACK/NAK Item on Not on FileSTX/ETX Ascii BCDSET STX SET ETX SET SET STX/ETX ENDWhen to Acknowledge Wack Wack ACK RS-232 Feature onlyOption ① Option ➁ Option ➂ SYNC2 When to Beep OptionsNAK Wack ACK NAK SET Ption Beeper Volume OptionNormal Loud Radio Channel Frequency ChannelRadio Transmit Power Wait Time Wait Time for Host AcknowledgeWait Time for Host Acknowledge Verify EAN-13 Verify UPC-AVerify UPC-E Verify EAN-8ONE Read TWO Reads Three Reads Four Reads Verify CodeVerify Codabar Verify Code Verify MSI/PLESSEYBeep Twice No Beep LOW Battery Indication MethodUPC/EAN Factory DefaultsEnable DisableCode High Disable Item ON/OFF FileACK/NAK Protocol ETX/STXONE INTERFACE-DISCRETE DefaultsRS-232/KEYBOARD Wedge NoneIBM Interfaces 100Host Programming Creating Multifunction LabelsNeed More Information 102 MSI/PLESSEY UPC-A W/2 Digit ADD-ON UPC-A W/ 5 Digit ADD-ON UPC-E EAN-8104 Blank Germany Asia PacificAustralia France