PSC SP400rf manual SET SET Suffix, For the example in step five, scan 0, 7, 0

Page 36

SETTING NON-SYMBOLOGY SPECIFIC SUFFIX(ES)

These characters will be added to the standard label format when your system has specific and unique requirements for information added to the barcode label data before it is sent to the host. Suffix characters follow the label data.

Identify your specific system requirements before adding or modifying

these settings, then...

1.Look at the ASCII chart shown on page 33 and identify the ASCII character(s) and the corresponding Hex Code(s) for the ASCII characters you will use as suffixes.

For example, if you are going to send two suffix characters as 'BEL' (sound host tone) and 'ETX' (end transmission). The ASCII chart shows that 'BEL' equals 07hex and 'ETX' equals 03hex.

2.Scan the SET label.

3.Scan the Set Suffix label on this page.

4.Scan the digits that correspond to the Hex Values.

For the example in step five, scan 0, 7, 0, 3.

NOTE

If you make a mistake, or lose your place while setting this option, scan the “end” label to exit Programming Mode. The scanner will sound a rejection tone (a “good beep” followed by a low “bad beep”) to indicate that programming was incomplete, and the setting will remain as it was before entering Programming Mode.

5.Scan END.

You have added a two character suffix to all label data, regardless of label symbology, that will be added to the label data before it is sent to the host.

LABEL TRANSMIT FORMAT CONFIG

SET -------------------------------------

SET SUFFIX -------------------

GO TO THE NEXT TWO PAGES AND SCAN THE APPROPRIATE CHARACTERS BEFORE SCANNING THE END LABEL TO EXIT PROGRAMMING SESSION.

30

SP400RF Programming Guide

Image 36
Contents Handheld Laser Scanner PSC Scanning, Inc DisclaimerContents RS-232 Iii SP400RF Programming Guide Need to Understand the Basics Integrating Peripherals with Host SystemsChanging Interfaces SP400RF Interface GroupsCustomizing Your Scanner Operation What is Programming MODE? HOW to Program Using BarcodesProgramming Overview Scanner Response When in Programming Mode Programming SessionReturn to Factory Settings Configuration UploadSET ENDWhere to GO from Here IBM 4683/84 4693/94 Port 5B Settings IBM 4683/84 4693/94 Port 5B Interface SELECTION1IBM 4683/84 4693/94 Port 9A, 9B, 9C, 9E Settings SET Send AS CodeIBM 4682/92 Port E Settings IBM 4682/92 Port E Interface SelectionPSC1 Ocia Interface Selection NCR Ocia Nine BIT Long Format Interface SelectionSNI Ocia Interface Selection SET NableIsable Nable IsableFull Ascii Wand Emulation Interface SelectionLOW HighC128 ENDCommunication Parameter RS-232 Interface SelectionSNI RS-232 Interface Selection Data Bits Start Bit Parity Bits Stop Bits Data Format Settings Hardware Control Software Control SET = N ONE = 90 Milliseconds = 100 Milliseconds PC Keyboard Wedge Interface Selection TypeEyboard Wedge Interface Intercharacter Delay = 55 Milliseconds Ibmxxxx STI Wedge STI Keyboard Wedge Interface SelectionLabel Transmit Format Configuration Items RS-232AND Keyboard Wedge Interfaces onlyPrefix & Suffix Label Transmit Format Config SET SET Prefix For the example in step four, scan 0, 2, 2SET SET Suffix For the example in step five, scan 0, 7, 0Setting a Single Character Prefix or Suffix ONE Character only ~ 7E Del Ascii Character SETUPC-A Our example, we would scan the UPC-A symbology label UPC-A UPC-EEAN-8 EAN-13Code Codabar Interleaved 2 Standard 2 MSI/PLESSEY Scan the barcodes values Disabling Label I.D. for a Specific Symbology Label Transmit Format Config Interface Type UPC/EANCode Symbology Options Overview Symbology Selection Enable UPC/EAN Disable UPC/EAN Enable Code Disable CodeEnable Codabar Disable Codabar Enable Code Disable Code Enable MSI/PLESSEY Disable MSI/PLESSEYUPC/EAN Options UPC/EAN Expansion Disabled END OptionalRequired Sendcheck Digit UPC-ESET EAN-8 Send Check DigitPRICE/WEIGHT Check Digit Code 39 Options Ascii Scan the Set Code 39 Minimum Label Length barcode Code 39 Minimum Label Length Interleaved 2 Enable DisableSET Dont Compute ComputeScan the Enable First Fixed barcode SET Fixed Engths Standard 2 Iata Standard 2 Normal or Iata SelectionDont Compute Dont Transmit Enable Disable Scan the Enable First Fixed barcode Standard 2 of 5 Fixed and Minimum Label Lengths Codabar Options Codabar Check Digit & Variable Length TRANSMIT1 Format = abcd/tn*eCodabar START/STOP Character Codabar Fixed Length SETScan the Set Second Fixed Length label ONE Check Digit TWO Check DigitsMSI/PLESSEY Check Digit MSI/PLESSEY Fixed Length MSI/PLESSEY SET Fixed Lengths Code 128 Options General Features General Features Communications ProtocolEnable Disable ACK/NAKItem on Not on File ENDSTX/ETX BCD AsciiSET SET STX/ETX END SET STX SET ETXWhen to Acknowledge Wack RS-232 Feature only Wack ACKOption ① Option ➁ Option ➂ When to Beep Options SYNC2NAK Wack ACK NAK SET Ption Beeper Volume OptionNormal Loud Channel Radio Channel FrequencyRadio Transmit Power Wait Time for Host Acknowledge Wait TimeWait Time for Host Acknowledge Verify UPC-A Verify UPC-EVerify EAN-8 Verify EAN-13Verify Code Verify Codabar Verify CodeVerify MSI/PLESSEY ONE Read TWO Reads Three Reads Four ReadsLOW Battery Indication Method Beep Twice No BeepFactory Defaults EnableDisable UPC/EANCode Disable Item ON/OFF File ACK/NAK ProtocolETX/STX HighINTERFACE-DISCRETE Defaults RS-232/KEYBOARD WedgeNone ONE100 IBM InterfacesHost Programming Creating Multifunction LabelsNeed More Information 102 UPC-A W/2 Digit ADD-ON UPC-A W/ 5 Digit ADD-ON UPC-E EAN-8 MSI/PLESSEY104 Blank Asia Pacific AustraliaFrance Germany