PSC SP400rf manual RS-232

Page 4

RS-232

 

RS-232 Interface Selection

15

SNI RS-232 Interface Selection

15

Hardware Control

18

Software Control

19

Keyboard Wedge

 

PC Keyboard Wedge Interface Selection

22

PC Keyboard Wedge –

 

Connect to a Laptop/No Keyboard Attached

23

STI Keyboard Wedge Interface Selection

26

Label Transmit Format Configuration Items

27

Prefix & Suffix

27

ASCII Character Set

33

Symbologies

 

Symbology Options Overview

42

Symbology Selection

43

UPC/EAN Options

45

UPC/EAN Expansion

46

UPC/EAN Add-Ons

47

Price/Weight Check Digit

50

Code 39 Options

51

Interleaved 2 of 5

55

Check Digit and Variable Length Label Selections . 56

Standard 2 of 5

60

Normal or IATA Selection

61

Check Digit and Variable Length Label Selections . 62

Codabar Options

65

Codabar Check Digit & Variable Length

66

Codabar Start/Stop Character

67

Codabar Fixed Length

68

MSI/Plessey Options

70

MSI/Plessey Check Digit

70

MSI/Plessey Fixed Length

71

ii

SP400RF Programming Guide

Image 4
Contents Handheld Laser Scanner PSC Scanning, Inc DisclaimerContents RS-232 Iii SP400RF Programming Guide Need to Understand the Basics Integrating Peripherals with Host SystemsChanging Interfaces SP400RF Interface GroupsCustomizing Your Scanner Operation HOW to Program Using Barcodes What is Programming MODE?Programming Overview Scanner Response When in Programming Mode Programming SessionReturn to Factory Settings Configuration UploadSET ENDWhere to GO from Here IBM 4683/84 4693/94 Port 5B Settings IBM 4683/84 4693/94 Port 5B Interface SELECTION1IBM 4683/84 4693/94 Port 9A, 9B, 9C, 9E Settings SET Send AS CodeIBM 4682/92 Port E Settings IBM 4682/92 Port E Interface SelectionNCR Ocia Nine BIT Long Format Interface Selection PSC1 Ocia Interface SelectionSNI Ocia Interface Selection SET NableIsable Nable IsableFull Ascii Wand Emulation Interface SelectionLOW HighC128 ENDRS-232 Interface Selection Communication ParameterSNI RS-232 Interface Selection Data Bits Start Bit Parity Bits Stop Bits Data Format Settings Hardware Control Software Control SET = N ONE = 90 Milliseconds = 100 Milliseconds PC Keyboard Wedge Interface Selection TypeEyboard Wedge Interface Intercharacter Delay = 55 Milliseconds Ibmxxxx STI Wedge STI Keyboard Wedge Interface SelectionRS-232AND Keyboard Wedge Interfaces only Label Transmit Format Configuration ItemsPrefix & Suffix Label Transmit Format Config SET SET Prefix For the example in step four, scan 0, 2, 2SET SET Suffix For the example in step five, scan 0, 7, 0Setting a Single Character Prefix or Suffix ONE Character only ~ 7E Del Ascii Character SETUPC-A Our example, we would scan the UPC-A symbology label UPC-A UPC-EEAN-8 EAN-13Code Codabar Interleaved 2 Standard 2 MSI/PLESSEY Scan the barcodes values Disabling Label I.D. for a Specific Symbology Label Transmit Format Config UPC/EAN Interface TypeCode Symbology Options Overview Symbology Selection Enable UPC/EAN Disable UPC/EAN Enable Code Disable CodeEnable Codabar Disable Codabar Enable Code Disable Code Enable MSI/PLESSEY Disable MSI/PLESSEYUPC/EAN Options UPC/EAN Expansion Optional Disabled ENDRequired Sendcheck Digit UPC-ESET EAN-8 Send Check DigitPRICE/WEIGHT Check Digit Code 39 Options Ascii Scan the Set Code 39 Minimum Label Length barcode Code 39 Minimum Label Length Interleaved 2 Enable DisableSET Dont Compute ComputeScan the Enable First Fixed barcode SET Fixed Engths Standard 2 Iata Standard 2 Normal or Iata SelectionDont Compute Dont Transmit Enable Disable Scan the Enable First Fixed barcode Standard 2 of 5 Fixed and Minimum Label Lengths Codabar Options Codabar Check Digit & Variable Length Format = abcd/tn*e TRANSMIT1Codabar START/STOP Character Codabar Fixed Length SETScan the Set Second Fixed Length label TWO Check Digits ONE Check DigitMSI/PLESSEY Check Digit MSI/PLESSEY Fixed Length MSI/PLESSEY SET Fixed Lengths Code 128 Options General Features General Features Communications ProtocolEnable Disable ACK/NAKItem on Not on File ENDSTX/ETX BCD AsciiSET SET STX/ETX END SET STX SET ETXWhen to Acknowledge Wack RS-232 Feature only Wack ACKOption ① Option ➁ Option ➂ When to Beep Options SYNC2NAK Wack ACK NAK SET Ption Option Beeper VolumeNormal Loud Channel Radio Channel FrequencyRadio Transmit Power Wait Time for Host Acknowledge Wait TimeWait Time for Host Acknowledge Verify UPC-A Verify UPC-EVerify EAN-8 Verify EAN-13Verify Code Verify Codabar Verify CodeVerify MSI/PLESSEY ONE Read TWO Reads Three Reads Four ReadsLOW Battery Indication Method Beep Twice No BeepFactory Defaults EnableDisable UPC/EANCode Disable Item ON/OFF File ACK/NAK ProtocolETX/STX HighINTERFACE-DISCRETE Defaults RS-232/KEYBOARD WedgeNone ONE100 IBM InterfacesCreating Multifunction Labels Host ProgrammingNeed More Information 102 UPC-A W/2 Digit ADD-ON UPC-A W/ 5 Digit ADD-ON UPC-E EAN-8 MSI/PLESSEY104 Blank Asia Pacific AustraliaFrance Germany