SYMBOLOGY SELECTION
SYMBOLOGY OPTIONS OVERVIEW
Enable All Symbologies — allows the scanner to
Disable All Symbologies — disables all symbologies. The scanner will only recognize the programming labels contained in this manual while you are in Programming Mode.
Enable UPC/EAN — tells the scanner to recognize
Enable Code 39 — selects Code 39 as an active symbology. Allows selection of Check Digit, Start/Stop and Single Digit options.
Enable Interleaved 2 of 5 — selects Interleaved 2 of 5 as an active symbology. Allows change of Check Digit or label format (fixed or variable length) options.
Enable Standard 2 of 5 — selects Standard 2 of 5 as an active symbology. Allows change of Check Digit or label format (fixed or variable length) options.
Enable Codabar — selects Codabar as an active symbology. Allows selection of Check Digit, Start/Stop character and format, or label format (fixed or variable length) options.
Enable Code 93 — selects Code 93 as an active symbology. The scanner is preset to recognize all Code 93 barcodes that have between 2 and 50 characters. Code 93 has no user selectable options.
Enable Code 128 — selects Code 128 as an active symbology. The scanner is preset to recognize all Code 128 barcodes that have between 2 and 50 characters. Code 128 has no user selectable options.
Enable MSI/Plessey — selects MSI/Plessey as an active symbology. Allows selection of Check Digit or label format (fixed or variable length) options.
42 | SP400RF Programming Guide |