PSC SP400rf manual Symbology Options Overview

Page 48

SYMBOLOGY SELECTION

SYMBOLOGY OPTIONS OVERVIEW

Enable All Symbologies — allows the scanner to auto-discriminate between all the symbologies in this list. Use this selection only if you must constantly read a wide variety of symbologies. Turn to the following pages for enabling additional symbology specific options.

Disable All Symbologies — disables all symbologies. The scanner will only recognize the programming labels contained in this manual while you are in Programming Mode.

Enable UPC/EAN — tells the scanner to recognize UPC-A, UPC-E, EAN-8, and EAN-13. If you enable this symbology, additional options for symbology expansion and reading add-ons are available. Allows selection of expansion and add-on options.

Enable Code 39 — selects Code 39 as an active symbology. Allows selection of Check Digit, Start/Stop and Single Digit options.

Enable Interleaved 2 of 5 — selects Interleaved 2 of 5 as an active symbology. Allows change of Check Digit or label format (fixed or variable length) options.

Enable Standard 2 of 5 — selects Standard 2 of 5 as an active symbology. Allows change of Check Digit or label format (fixed or variable length) options.

Enable Codabar — selects Codabar as an active symbology. Allows selection of Check Digit, Start/Stop character and format, or label format (fixed or variable length) options.

Enable Code 93 — selects Code 93 as an active symbology. The scanner is preset to recognize all Code 93 barcodes that have between 2 and 50 characters. Code 93 has no user selectable options.

Enable Code 128 — selects Code 128 as an active symbology. The scanner is preset to recognize all Code 128 barcodes that have between 2 and 50 characters. Code 128 has no user selectable options.

Enable MSI/Plessey — selects MSI/Plessey as an active symbology. Allows selection of Check Digit or label format (fixed or variable length) options.

42

SP400RF Programming Guide

Image 48
Contents Handheld Laser Scanner PSC Scanning, Inc DisclaimerContents RS-232 Iii SP400RF Programming Guide Need to Understand the Basics Integrating Peripherals with Host SystemsChanging Interfaces SP400RF Interface GroupsCustomizing Your Scanner Operation What is Programming MODE? HOW to Program Using BarcodesProgramming Overview Scanner Response When in Programming Mode Programming SessionReturn to Factory Settings Configuration UploadSET ENDWhere to GO from Here IBM 4683/84 4693/94 Port 5B Settings IBM 4683/84 4693/94 Port 5B Interface SELECTION1IBM 4683/84 4693/94 Port 9A, 9B, 9C, 9E Settings SET Send AS CodeIBM 4682/92 Port E Settings IBM 4682/92 Port E Interface SelectionPSC1 Ocia Interface Selection NCR Ocia Nine BIT Long Format Interface SelectionSNI Ocia Interface Selection SET NableIsable Nable IsableFull Ascii Wand Emulation Interface SelectionLOW HighC128 ENDCommunication Parameter RS-232 Interface SelectionSNI RS-232 Interface Selection Data Bits Start Bit Parity Bits Stop Bits Data Format Settings Hardware Control Software Control SET = N ONE = 90 Milliseconds = 100 Milliseconds PC Keyboard Wedge Interface Selection TypeEyboard Wedge Interface Intercharacter Delay = 55 Milliseconds Ibmxxxx STI Wedge STI Keyboard Wedge Interface SelectionLabel Transmit Format Configuration Items RS-232AND Keyboard Wedge Interfaces onlyPrefix & Suffix Label Transmit Format Config SET SET Prefix For the example in step four, scan 0, 2, 2SET SET Suffix For the example in step five, scan 0, 7, 0Setting a Single Character Prefix or Suffix ONE Character only ~ 7E Del Ascii Character SETUPC-A Our example, we would scan the UPC-A symbology label UPC-A UPC-EEAN-8 EAN-13Code Codabar Interleaved 2 Standard 2 MSI/PLESSEY Scan the barcodes values Disabling Label I.D. for a Specific Symbology Label Transmit Format Config Interface Type UPC/EANCode Symbology Options Overview Symbology Selection Enable UPC/EAN Disable UPC/EAN Enable Code Disable CodeEnable Codabar Disable Codabar Enable Code Disable Code Enable MSI/PLESSEY Disable MSI/PLESSEYUPC/EAN Options UPC/EAN Expansion Disabled END OptionalRequired Sendcheck Digit UPC-ESET EAN-8 Send Check DigitPRICE/WEIGHT Check Digit Code 39 Options Ascii Scan the Set Code 39 Minimum Label Length barcode Code 39 Minimum Label Length Interleaved 2 Enable DisableSET Dont Compute ComputeScan the Enable First Fixed barcode SET Fixed Engths Standard 2 Iata Standard 2 Normal or Iata SelectionDont Compute Dont Transmit Enable Disable Scan the Enable First Fixed barcode Standard 2 of 5 Fixed and Minimum Label Lengths Codabar Options Codabar Check Digit & Variable Length TRANSMIT1 Format = abcd/tn*eCodabar START/STOP Character Codabar Fixed Length SETScan the Set Second Fixed Length label ONE Check Digit TWO Check DigitsMSI/PLESSEY Check Digit MSI/PLESSEY Fixed Length MSI/PLESSEY SET Fixed Lengths Code 128 Options General Features General Features Communications ProtocolEnable Disable ACK/NAKItem on Not on File ENDSTX/ETX BCD AsciiSET SET STX/ETX END SET STX SET ETXWhen to Acknowledge Wack RS-232 Feature only Wack ACKOption ① Option ➁ Option ➂ When to Beep Options SYNC2NAK Wack ACK NAK SET Ption Beeper Volume OptionNormal Loud Channel Radio Channel FrequencyRadio Transmit Power Wait Time for Host Acknowledge Wait TimeWait Time for Host Acknowledge Verify UPC-A Verify UPC-EVerify EAN-8 Verify EAN-13Verify Code Verify Codabar Verify CodeVerify MSI/PLESSEY ONE Read TWO Reads Three Reads Four ReadsLOW Battery Indication Method Beep Twice No BeepFactory Defaults EnableDisable UPC/EANCode Disable Item ON/OFF File ACK/NAK ProtocolETX/STX HighINTERFACE-DISCRETE Defaults RS-232/KEYBOARD WedgeNone ONE100 IBM InterfacesHost Programming Creating Multifunction LabelsNeed More Information 102 UPC-A W/2 Digit ADD-ON UPC-A W/ 5 Digit ADD-ON UPC-E EAN-8 MSI/PLESSEY104 Blank Asia Pacific AustraliaFrance Germany