PSC SP400rf manual IBM 4683/84 4693/94 Port 5B Interface SELECTION1

Page 14

IBM INTERFACES

IBM 4683/84 • 4693/94 PORT 5B INTERFACE SELECTION1

Scan this label to enable the IBM 468x Port 5B interface1.

IBM 4683/84 • 4693/94 PORT 5B SETTINGS

Data Format: Send As Code 39 — converts barcode data (UPC/EAN, add- ons, Code 93, Codabar, MSI/Plessey and Code 128) into Code 39 format before sending the data to the host.

These settings are for IBM 4683/84 • 4693/94 Port 5B interface ONLY.

Limit Command Set — is an option that causes the scanner to ignore 'enable scanner' and 'disable scanner' commands sent from the host.

Transmit Unsolicited Status2 — when enabled, this option causes the scanner to transmit a status message to the host upon receipt of a "Set Normal Response Mode" (SNRM) command, and after scanner transmission of a "Non Sequenced Acknowledge" (NSA) response.

SET -------------------------------------

 

 

SEND AS CODE 39 ------------

 

 

DON'T SEND AS CODE 39 ------

FORMAT

 

ENABLE LIMIT COMMAND SET ---

DATA

 

 

DISABLE LIMIT COMMAND SET --

 

 

 

 

TRANSMIT UNSOLICITED STATUS -

 

 

ON'T TRANSMIT UNSOLICITED STATUS

 

D

END -------------------------------------

1Scanners manufactured prior to April 30, 1997 do not have IBM interfaces as a selectable option.

2For this IBM interface, the setting for Unsolicited Status is normally Enabled.

8

SP400RF Programming Guide

Image 14
Contents Handheld Laser Scanner PSC Scanning, Inc DisclaimerContents RS-232 Iii SP400RF Programming Guide Need to Understand the Basics Integrating Peripherals with Host SystemsChanging Interfaces SP400RF Interface GroupsCustomizing Your Scanner Operation Programming Overview What is Programming MODE?HOW to Program Using Barcodes Scanner Response When in Programming Mode Programming SessionSET Return to Factory SettingsConfiguration Upload ENDWhere to GO from Here IBM 4683/84 4693/94 Port 5B Settings IBM 4683/84 4693/94 Port 5B Interface SELECTION1IBM 4683/84 4693/94 Port 9A, 9B, 9C, 9E Settings SET Send AS CodeIBM 4682/92 Port E Settings IBM 4682/92 Port E Interface SelectionSNI Ocia Interface Selection PSC1 Ocia Interface SelectionNCR Ocia Nine BIT Long Format Interface Selection Isable SETNable Nable IsableFull Ascii Wand Emulation Interface SelectionC128 LOWHigh ENDSNI RS-232 Interface Selection Communication ParameterRS-232 Interface Selection Data Bits Start Bit Parity Bits Stop Bits Data Format Settings Hardware Control Software Control SET = N ONE = 90 Milliseconds = 100 Milliseconds PC Keyboard Wedge Interface Selection TypeEyboard Wedge Interface Intercharacter Delay = 55 Milliseconds Ibmxxxx STI Wedge STI Keyboard Wedge Interface SelectionPrefix & Suffix Label Transmit Format Configuration ItemsRS-232AND Keyboard Wedge Interfaces only Label Transmit Format Config SET SET Prefix For the example in step four, scan 0, 2, 2SET SET Suffix For the example in step five, scan 0, 7, 0Setting a Single Character Prefix or Suffix ONE Character only ~ 7E Del Ascii Character SETUPC-A Our example, we would scan the UPC-A symbology label EAN-8 UPC-AUPC-E EAN-13Code Codabar Interleaved 2 Standard 2 MSI/PLESSEY Scan the barcodes values Disabling Label I.D. for a Specific Symbology Label Transmit Format Config Code Interface TypeUPC/EAN Symbology Options Overview Symbology Selection Enable UPC/EAN Disable UPC/EAN Enable Code Disable CodeEnable Codabar Disable Codabar Enable Code Disable Code Enable MSI/PLESSEY Disable MSI/PLESSEYUPC/EAN Options UPC/EAN Expansion Required Disabled ENDOptional Sendcheck Digit UPC-ESET EAN-8 Send Check DigitPRICE/WEIGHT Check Digit Code 39 Options Ascii Scan the Set Code 39 Minimum Label Length barcode Code 39 Minimum Label Length Interleaved 2 SET Dont Compute EnableDisable ComputeScan the Enable First Fixed barcode SET Fixed Engths Standard 2 Iata Standard 2 Normal or Iata SelectionDont Compute Dont Transmit Enable Disable Scan the Enable First Fixed barcode Standard 2 of 5 Fixed and Minimum Label Lengths Codabar Options Codabar Check Digit & Variable Length Codabar START/STOP Character TRANSMIT1Format = abcd/tn*e Codabar Fixed Length SETScan the Set Second Fixed Length label MSI/PLESSEY Check Digit ONE Check DigitTWO Check Digits MSI/PLESSEY Fixed Length MSI/PLESSEY SET Fixed Lengths Code 128 Options General Features General Features Communications ProtocolItem on Not on File Enable DisableACK/NAK ENDSTX/ETX BCD AsciiSET SET STX/ETX END SET STX SET ETXWhen to Acknowledge Wack RS-232 Feature only Wack ACKOption ① Option ➁ Option ➂ When to Beep Options SYNC2NAK Wack ACK NAK SET Ption Normal Loud Beeper VolumeOption Channel Radio Channel FrequencyRadio Transmit Power Wait Time for Host Acknowledge Wait TimeWait Time for Host Acknowledge Verify EAN-8 Verify UPC-AVerify UPC-E Verify EAN-13Verify MSI/PLESSEY Verify CodeVerify Codabar Verify Code ONE Read TWO Reads Three Reads Four ReadsLOW Battery Indication Method Beep Twice No BeepDisable Factory DefaultsEnable UPC/EANCode ETX/STX Disable Item ON/OFF FileACK/NAK Protocol HighNone INTERFACE-DISCRETE DefaultsRS-232/KEYBOARD Wedge ONE100 IBM InterfacesNeed More Information Host ProgrammingCreating Multifunction Labels 102 UPC-A W/2 Digit ADD-ON UPC-A W/ 5 Digit ADD-ON UPC-E EAN-8 MSI/PLESSEY104 Blank France Asia PacificAustralia Germany