E F E c o n f i g u r a t i o n

Bits

Access

Mnemonic

Reset

Description

 

 

 

 

 

D00

R/W

SCANI

0

Scan increment (single scan for read data)

 

 

 

 

When set to 1, the MII management module

 

 

 

 

performs read cycles across a range of PHY

 

 

 

 

devices, from address 1 through the value set in

 

 

 

 

the RADR field in the MII Address register (see

 

 

 

 

page 194).

 

 

 

 

 

Table 69: MII Management Configuration register bit definition

CLKS field

SYS_CLK ratio

75 MHz example

12 MHz example

 

 

 

 

000

SYS_CLK / 4

 

 

 

 

 

 

001

SYS_CLK / 4

 

 

 

 

 

 

010

SYS_CLK / 6

 

2.0 MHz

 

 

 

 

011

SYS_CLK / 8

 

 

 

 

 

 

100

SYS_CLK / 10

 

 

 

 

 

 

101

SYS_CLK / 14

 

 

 

 

 

 

110

SYS_CLK / 20

 

 

 

 

 

 

111

SYS_CLK / 28

2.4 MHz

 

 

 

 

 

Table 70: CLKS field settings

1 9 2

N S 7 5 2 0 H a r d w a r e R e f e r e n c e , R e v . D 0 3 / 2 0 0 6

Page 206
Image 206
Digi NS7520 Clks field settings, Scani, Scan increment single scan for read data, Clks field Sysclk ratio MHz example