E t h e r n e t M o d u l e

Bits

Access

Mnemonic

Reset

Description

 

 

 

 

 

D02

R/W

HUGE

0

Huge frame enable

 

 

 

 

When this bit is set to 1, frames of any length are

 

 

 

 

transmitted and received.

 

 

 

 

 

D01

R/W

FLENC

0

Frame length checking

 

 

 

 

When set to 1, both transmit and receive frame

 

 

 

 

lengths are compared to the Length/Type field. If

 

 

 

 

the Length/Type field represents a length, the

 

 

 

 

check is performed. Mismatches are reported on

 

 

 

 

the transmit/receive statistics vector.

 

 

 

 

 

D00

R/W

FULLD

0

Full duplex

 

 

 

 

1 The MAC operates in full-duplex mode.

 

 

 

 

0 The MAC operates in half-duplex mode.

It is recommended that you limit transmit frames to 512 bytes when full-duplex operation is enabled.

Table 61: MAC Configuration Register 2 bit definition

Pad operation table

This table provides a description of the pad function based on the configuration of the AUTOP field.

Type

AUTOP

VLANP

PADEN

Action

 

 

 

 

 

Any

X

X

0

No pad; check CRC.

 

 

 

 

 

Any

0

0

0

Pad to 60 bytes; append CRC.

 

 

 

 

 

Any

X

1

1

Pad to 64 bytes; append CRC.

 

 

 

 

 

Any

1

0

1

If untagged, pad to 60 bytes and

 

 

 

 

append CRC.

If VLAN-tagged, pad to 64 bytes and append CRC.

Table 62: PAD operation