PSC SP400rf manual Scan the barcodes values

Page 44

LABEL TRANSMIT FORMAT CONFIG

HOW TO SET SINGLE CHARACTER LABEL I.D.

If you only want a single character identifier, follow this modified proce- dure for setting label identifier.

1.Look at the ASCII chart shown on page 33 and identify the ASCII character and the corresponding Hex Code for the ASCII character you will use as the symbology specific identifier.

2.Scan the SET label.

3.Scan the label identifier label for the symbology identifier that you are going to change.

As an example, assume that you want to change the label identifier for EAN-8 from the default setting FF to the ASCII value 8. Scan the Set Symbology Specific Label Identifier barcode for EAN-8.

5.Identify the hex value that correspond to the ASCII character.

In this example '8' equals 38hex.

Simply follow the hex value for '8' (38hex) with the One Character Only label. This tells the scanner that '8' is a

single digit label identifier.

6.Scan the barcodes values.

For the example in step five, scan 3, 8, One Character Only on the following two pages.

NOTE

If you make a mistake, or lose your place while setting this option, scan the “end” label to exit Programming Mode. The scanner will sound a rejection tone (a “good beep” followed by a low “bad beep”) to indicate that programming was incomplete, and the setting will remain as it was before entering Programming Mode.

7.Scan the END label.

You have changed the default label identifier for EAN-8 from 'FF' to '8'.

38

SP400RF Programming Guide

Image 44
Contents Handheld Laser Scanner PSC Scanning, Inc DisclaimerContents RS-232 Iii SP400RF Programming Guide Need to Understand the Basics Integrating Peripherals with Host SystemsChanging Interfaces SP400RF Interface GroupsCustomizing Your Scanner Operation Programming Overview What is Programming MODE?HOW to Program Using Barcodes Scanner Response When in Programming Mode Programming SessionReturn to Factory Settings Configuration UploadSET ENDWhere to GO from Here IBM 4683/84 4693/94 Port 5B Settings IBM 4683/84 4693/94 Port 5B Interface SELECTION1IBM 4683/84 4693/94 Port 9A, 9B, 9C, 9E Settings SET Send AS CodeIBM 4682/92 Port E Settings IBM 4682/92 Port E Interface SelectionSNI Ocia Interface Selection PSC1 Ocia Interface SelectionNCR Ocia Nine BIT Long Format Interface Selection SET NableIsable Nable IsableFull Ascii Wand Emulation Interface SelectionLOW HighC128 ENDSNI RS-232 Interface Selection Communication ParameterRS-232 Interface Selection Data Bits Start Bit Parity Bits Stop Bits Data Format Settings Hardware Control Software Control SET = N ONE = 90 Milliseconds = 100 Milliseconds PC Keyboard Wedge Interface Selection TypeEyboard Wedge Interface Intercharacter Delay = 55 Milliseconds Ibmxxxx STI Wedge STI Keyboard Wedge Interface SelectionPrefix & Suffix Label Transmit Format Configuration ItemsRS-232AND Keyboard Wedge Interfaces only Label Transmit Format Config SET SET Prefix For the example in step four, scan 0, 2, 2SET SET Suffix For the example in step five, scan 0, 7, 0Setting a Single Character Prefix or Suffix ONE Character only ~ 7E Del Ascii Character SETUPC-A Our example, we would scan the UPC-A symbology label UPC-A UPC-EEAN-8 EAN-13Code Codabar Interleaved 2 Standard 2 MSI/PLESSEY Scan the barcodes values Disabling Label I.D. for a Specific Symbology Label Transmit Format Config Code Interface TypeUPC/EAN Symbology Options Overview Symbology Selection Enable UPC/EAN Disable UPC/EAN Enable Code Disable CodeEnable Codabar Disable Codabar Enable Code Disable Code Enable MSI/PLESSEY Disable MSI/PLESSEYUPC/EAN Options UPC/EAN Expansion Required Disabled ENDOptional Sendcheck Digit UPC-ESET EAN-8 Send Check DigitPRICE/WEIGHT Check Digit Code 39 Options Ascii Scan the Set Code 39 Minimum Label Length barcode Code 39 Minimum Label Length Interleaved 2 Enable DisableSET Dont Compute ComputeScan the Enable First Fixed barcode SET Fixed Engths Standard 2 Iata Standard 2 Normal or Iata SelectionDont Compute Dont Transmit Enable Disable Scan the Enable First Fixed barcode Standard 2 of 5 Fixed and Minimum Label Lengths Codabar Options Codabar Check Digit & Variable Length Codabar START/STOP Character TRANSMIT1Format = abcd/tn*e Codabar Fixed Length SETScan the Set Second Fixed Length label MSI/PLESSEY Check Digit ONE Check DigitTWO Check Digits MSI/PLESSEY Fixed Length MSI/PLESSEY SET Fixed Lengths Code 128 Options General Features General Features Communications ProtocolEnable Disable ACK/NAKItem on Not on File ENDSTX/ETX BCD AsciiSET SET STX/ETX END SET STX SET ETXWhen to Acknowledge Wack RS-232 Feature only Wack ACKOption ① Option ➁ Option ➂ When to Beep Options SYNC2NAK Wack ACK NAK SET Ption Normal Loud Beeper VolumeOption Channel Radio Channel FrequencyRadio Transmit Power Wait Time for Host Acknowledge Wait TimeWait Time for Host Acknowledge Verify UPC-A Verify UPC-EVerify EAN-8 Verify EAN-13Verify Code Verify Codabar Verify CodeVerify MSI/PLESSEY ONE Read TWO Reads Three Reads Four ReadsLOW Battery Indication Method Beep Twice No BeepFactory Defaults EnableDisable UPC/EANCode Disable Item ON/OFF File ACK/NAK ProtocolETX/STX HighINTERFACE-DISCRETE Defaults RS-232/KEYBOARD WedgeNone ONE100 IBM InterfacesNeed More Information Host ProgrammingCreating Multifunction Labels 102 UPC-A W/2 Digit ADD-ON UPC-A W/ 5 Digit ADD-ON UPC-E EAN-8 MSI/PLESSEY104 Blank Asia Pacific AustraliaFrance Germany