The Codabar symbology has the following programmable features:

Check Digit — calculate the Check Digit to verify the labels contents have been read correctly. If you enable this feature, your barcodes must include a Check Digit. You may also choose to transmit or not transmit the Check Digit.

Start/Stop Characters — you can choose either Send or Don't Send depending on your host's interface requirement.

Start/Stop Format — if you need to send the Start/Stop characters, there are four standard format options that you can select from; ABCD/TN*E, ABCD/ABCD, abcd/tn*e, or abcd/abcd. This setting must match your system require- ments. If you select one of these options, it determines how the ASCII characters A, B, C, D that are used for Start/Stop characters, will be translated before being sent to the host.

Start/Stop Match — the requirement that the Start and Stop characters must match (be identical) can be enabled or disabled.

Label Format — provides the selection between fixed or variable length labels. If your application has labels with specific fixed length, we recommend selecting fixed lengths to improve read rate.

If you select variable length, the scanner will recognize labels with between 2 and 47 digits (not including the optional check digit).

Set First Fixed Length — if you select fixed length, use this feature to set a first fixed label length to a setting be- tween 2 and 47 digits.

Set Second Fixed Length — if you select fixed length, use this feature to set a second fixed label length to a setting between 2 and 47 digits.

No Second Fixed Length — scan this label after setting the first fixed length to instruct the scanner to recognize only the label length chosen as the first label length.

Gap Check — allows the scanner to combine two label halves printed in close proximity to each other that may have been printed at different times and perhaps different locations.

R44-1027

65

SYMBOLOGY SELECTION

Image 71
Contents Handheld Laser Scanner Disclaimer PSC Scanning, IncContents RS-232 Iii SP400RF Programming Guide Integrating Peripherals with Host Systems Need to Understand the BasicsSP400RF Interface Groups Changing InterfacesCustomizing Your Scanner Operation Programming Overview What is Programming MODE?HOW to Program Using Barcodes Programming Session Scanner Response When in Programming ModeEND Return to Factory SettingsConfiguration Upload SETWhere to GO from Here IBM 4683/84 4693/94 Port 5B Interface SELECTION1 IBM 4683/84 4693/94 Port 5B SettingsSET Send AS Code IBM 4683/84 4693/94 Port 9A, 9B, 9C, 9E SettingsIBM 4682/92 Port E Interface Selection IBM 4682/92 Port E SettingsSNI Ocia Interface Selection PSC1 Ocia Interface SelectionNCR Ocia Nine BIT Long Format Interface Selection Nable Isable SETNable IsableWand Emulation Interface Selection Full AsciiEND LOWHigh C128SNI RS-232 Interface Selection Communication ParameterRS-232 Interface Selection Data Bits Start Bit Parity Bits Stop Bits Data Format Settings Hardware Control Software Control SET = N ONE = 90 Milliseconds = 100 Milliseconds Type PC Keyboard Wedge Interface SelectionEyboard Wedge Interface Intercharacter Delay = 55 Milliseconds STI Keyboard Wedge Interface Selection Ibmxxxx STI WedgePrefix & Suffix Label Transmit Format Configuration ItemsRS-232AND Keyboard Wedge Interfaces only Label Transmit Format Config For the example in step four, scan 0, 2, 2 SET SET PrefixFor the example in step five, scan 0, 7, 0 SET SET SuffixSetting a Single Character Prefix or Suffix ONE Character only Ascii Character SET ~ 7E DelUPC-A Our example, we would scan the UPC-A symbology label EAN-13 UPC-AUPC-E EAN-8Code Codabar Interleaved 2 Standard 2 MSI/PLESSEY Scan the barcodes values Disabling Label I.D. for a Specific Symbology Label Transmit Format Config Code Interface TypeUPC/EAN Symbology Options Overview Enable UPC/EAN Disable UPC/EAN Enable Code Disable Code Symbology SelectionEnable MSI/PLESSEY Disable MSI/PLESSEY Enable Codabar Disable Codabar Enable Code Disable CodeUPC/EAN Options UPC/EAN Expansion Required Disabled ENDOptional UPC-E Sendcheck DigitSend Check Digit SET EAN-8PRICE/WEIGHT Check Digit Code 39 Options Ascii Scan the Set Code 39 Minimum Label Length barcode Code 39 Minimum Label Length Interleaved 2 Compute EnableDisable SET Dont ComputeScan the Enable First Fixed barcode SET Fixed Engths Standard 2 Normal or Iata Selection Iata Standard 2Dont Compute Dont Transmit Enable Disable Scan the Enable First Fixed barcode Standard 2 of 5 Fixed and Minimum Label Lengths Codabar Options Codabar Check Digit & Variable Length Codabar START/STOP Character TRANSMIT1Format = abcd/tn*e SET Codabar Fixed LengthScan the Set Second Fixed Length label MSI/PLESSEY Check Digit ONE Check DigitTWO Check Digits MSI/PLESSEY Fixed Length MSI/PLESSEY SET Fixed Lengths Code 128 Options General Features Communications Protocol General FeaturesEND Enable DisableACK/NAK Item on Not on FileSTX/ETX Ascii BCDSET STX SET ETX SET SET STX/ETX ENDWhen to Acknowledge Wack Wack ACK RS-232 Feature onlyOption ① Option ➁ Option ➂ SYNC2 When to Beep OptionsNAK Wack ACK NAK SET Ption Normal Loud Beeper VolumeOption Radio Channel Frequency ChannelRadio Transmit Power Wait Time Wait Time for Host AcknowledgeWait Time for Host Acknowledge Verify EAN-13 Verify UPC-AVerify UPC-E Verify EAN-8ONE Read TWO Reads Three Reads Four Reads Verify CodeVerify Codabar Verify Code Verify MSI/PLESSEYBeep Twice No Beep LOW Battery Indication MethodUPC/EAN Factory DefaultsEnable DisableCode High Disable Item ON/OFF FileACK/NAK Protocol ETX/STXONE INTERFACE-DISCRETE DefaultsRS-232/KEYBOARD Wedge NoneIBM Interfaces 100Need More Information Host ProgrammingCreating Multifunction Labels 102 MSI/PLESSEY UPC-A W/2 Digit ADD-ON UPC-A W/ 5 Digit ADD-ON UPC-E EAN-8104 Blank Germany Asia PacificAustralia France