PSC SP400rf manual Communication Parameter, SNI RS-232 Interface Selection

Page 21

RS-232 INTERFACE SELECTION

Scan this label to enable the RS-232 interface.

SNI RS-232 INTERFACE SELECTION

Scan this label to enable the SNI RS-232 interface.

Turn to the following pages to set the RS-232 communication parameters.

Communication Parameter

Page #

Baud Rate ------------------------------------------------------------------

16

Data Bits -------------------------------------------------------------------

17

Parity ------------------------------------------------------------------------

17

Stop Bit(s) -----------------------------------------------------------------

17

Hardware Handshaking (CTS/RTS) ---------------------------------

18

Software Handshaking (Xon/Xoff) ----------------------------------

19

Intercharacter Delay ----------------------------------------------------

20

Go to the sections titled Symbology Selection and General Features in the back of this programming guide if you want to change any other factory settings for this interface.

RS-232

INTERFACE

R44-1027

15

Image 21
Contents Handheld Laser Scanner Disclaimer PSC Scanning, IncContents RS-232 Iii SP400RF Programming Guide Integrating Peripherals with Host Systems Need to Understand the BasicsSP400RF Interface Groups Changing InterfacesCustomizing Your Scanner Operation What is Programming MODE? HOW to Program Using BarcodesProgramming Overview Programming Session Scanner Response When in Programming ModeConfiguration Upload Return to Factory SettingsSET ENDWhere to GO from Here IBM 4683/84 4693/94 Port 5B Interface SELECTION1 IBM 4683/84 4693/94 Port 5B SettingsSET Send AS Code IBM 4683/84 4693/94 Port 9A, 9B, 9C, 9E SettingsIBM 4682/92 Port E Interface Selection IBM 4682/92 Port E SettingsPSC1 Ocia Interface Selection NCR Ocia Nine BIT Long Format Interface SelectionSNI Ocia Interface Selection Nable SETIsable Nable IsableWand Emulation Interface Selection Full AsciiHigh LOWC128 ENDCommunication Parameter RS-232 Interface SelectionSNI RS-232 Interface Selection Data Bits Start Bit Parity Bits Stop Bits Data Format Settings Hardware Control Software Control SET = N ONE = 90 Milliseconds = 100 Milliseconds Type PC Keyboard Wedge Interface SelectionEyboard Wedge Interface Intercharacter Delay = 55 Milliseconds STI Keyboard Wedge Interface Selection Ibmxxxx STI WedgeLabel Transmit Format Configuration Items RS-232AND Keyboard Wedge Interfaces onlyPrefix & Suffix Label Transmit Format Config For the example in step four, scan 0, 2, 2 SET SET PrefixFor the example in step five, scan 0, 7, 0 SET SET SuffixSetting a Single Character Prefix or Suffix ONE Character only Ascii Character SET ~ 7E DelUPC-A Our example, we would scan the UPC-A symbology label UPC-E UPC-AEAN-8 EAN-13Code Codabar Interleaved 2 Standard 2 MSI/PLESSEY Scan the barcodes values Disabling Label I.D. for a Specific Symbology Label Transmit Format Config Interface Type UPC/EANCode Symbology Options Overview Enable UPC/EAN Disable UPC/EAN Enable Code Disable Code Symbology SelectionEnable MSI/PLESSEY Disable MSI/PLESSEY Enable Codabar Disable Codabar Enable Code Disable CodeUPC/EAN Options UPC/EAN Expansion Disabled END OptionalRequired UPC-E Sendcheck DigitSend Check Digit SET EAN-8PRICE/WEIGHT Check Digit Code 39 Options Ascii Scan the Set Code 39 Minimum Label Length barcode Code 39 Minimum Label Length Interleaved 2 Disable EnableSET Dont Compute ComputeScan the Enable First Fixed barcode SET Fixed Engths Standard 2 Normal or Iata Selection Iata Standard 2Dont Compute Dont Transmit Enable Disable Scan the Enable First Fixed barcode Standard 2 of 5 Fixed and Minimum Label Lengths Codabar Options Codabar Check Digit & Variable Length TRANSMIT1 Format = abcd/tn*eCodabar START/STOP Character SET Codabar Fixed LengthScan the Set Second Fixed Length label ONE Check Digit TWO Check DigitsMSI/PLESSEY Check Digit MSI/PLESSEY Fixed Length MSI/PLESSEY SET Fixed Lengths Code 128 Options General Features Communications Protocol General FeaturesACK/NAK Enable DisableItem on Not on File ENDSTX/ETX Ascii BCDSET STX SET ETX SET SET STX/ETX ENDWhen to Acknowledge Wack Wack ACK RS-232 Feature onlyOption ① Option ➁ Option ➂ SYNC2 When to Beep OptionsNAK Wack ACK NAK SET Ption Beeper Volume OptionNormal Loud Radio Channel Frequency ChannelRadio Transmit Power Wait Time Wait Time for Host AcknowledgeWait Time for Host Acknowledge Verify UPC-E Verify UPC-AVerify EAN-8 Verify EAN-13Verify Codabar Verify Code Verify CodeVerify MSI/PLESSEY ONE Read TWO Reads Three Reads Four ReadsBeep Twice No Beep LOW Battery Indication MethodEnable Factory DefaultsDisable UPC/EANCode ACK/NAK Protocol Disable Item ON/OFF FileETX/STX HighRS-232/KEYBOARD Wedge INTERFACE-DISCRETE DefaultsNone ONEIBM Interfaces 100Host Programming Creating Multifunction LabelsNeed More Information 102 MSI/PLESSEY UPC-A W/2 Digit ADD-ON UPC-A W/ 5 Digit ADD-ON UPC-E EAN-8104 Blank Australia Asia PacificFrance Germany