Uniden UBC3300XLT manual Menu Description and Numeric Keypad Equivalents

Page 21

• ID Search mode/ID Search Hold mode

MENU MODE

1:SERVICE OPTION

2:SCAN OPTION

3:SYSTEM OPTION

Menu Description and Numeric Keypad Equivalents

Below are the Menu screens and a brief description or purpose of the feature.

1:SERVICE OPTION

1:AIR

The Air Service Search feature allows you to scroll through the preprogrammed services.

2:CHAIN SEARCH

You can program up to 10 search ranges. The first time you program a range you will need to do so through the Menu. After the first time you can program a range as you do on most any other scanner, using the numeric keypad or VFO control. Use this Menu item to select the search range that you want to program. You can program range 1 through 10, one at a time. For each of the ranges, the following options can be modified.

1:CHAIN SEARCH

You must turn Chain Search feature ON, in order to use the Chain Search feature.

2:SEARCH RANGE

1:RANGE

Enter the upper and lower frequency limits of the Search Range.

2:STEPS

You can assign a variety of step sizes to the search range.

Note: The default step is usually acceptable and is listed on page 1.

3:MODE

You can change the Auto receive mode to AM, FM, WFM, NFM.

17

Image 21
Contents Page Page Contents Edacs Scat LTR IntroductionFront View Icon Description Icon DisplayUBC3300XLT Shortcuts Then enter the trunk type you want to track. Press E Important Notice What is Searching? What is Scanning?What is Trunk Tracking? TerminologyPage Feature Highlights Page Information on the Internet Where to Obtain More InformationIncluded with Your Scanner Package Installing the Battery Pack SetupCharging the Battery Pack Low Battery IndicatorFlexible Antenna Connecting the Optional Remote CableBeltclip Listening SafelySetting the Squelch Basic OperationTurn the Scanner On Understanding the Menu System Menu Description and Numeric Keypad Equivalents Set attenuation for all search ranges. See 2SCAN 2SCAN Option 1CONVENTIONAL 6STEPS You can assign a variety of step sizes to the channel 8I-CALLMOTOROLA/EDACS 0EDACS ID Form Edacs 3SYSTEM Option 1DIMMER Select 2DISABLE in this mode Storing Frequencies into Channels in Menu Mode ProgrammingPress MENU/BACK Editing a Stored Frequency Deleting a Stored FrequencyDuplicate Frequency Alert 010 512.0000 FMStoring Text Tags Transfer FrequenciesPress HOLD/MAN Assigning a Bank Tag to a Bank Press MENU/BACKBeep Alert 855.0000Assigning the Beep Alert to a Channel Programming Tips Storing Frequencies During Scanning Scanning001 BankSetting the Delay Mode for Frequency RF Attenuation FeatureLockout in Scanning Mode Lockout in Hold Mode Press HOLD/MANChannel Lockout 001 141.5000 FM Uniden Group aRestoring a Locked-out Channel Restoring All Locked-out ChannelsPriority Scan Changing the Priority Channel Priority Channel Plus Scan001 512.0000 FM Setting a Search Range SearchingSrch 12.5k 1240.0000 FM Range Starting Chain Search Search Hold FeatureData Skip Srch 12.5k 1240.0000 FM Range 25cm Amateur GrpStoring Search Frequencies Frequency SkipAuto Storing 12.5k12--56 001 FM Bank Squelch SQ Mode001 FM DCS Bank 001 512.0000 FM Ctcss 250.3 Bank001 512.0000 FM Bank 003 512.0000 FM Ctcss Uniden Group aAdditional Menu Options for Searching Air Service Search Air Service Search SkipPress AIR/STEP Service Search AIR Programming Receiving Trunked Systems Selecting or Changing Trunking System Type001 0000.0000 LCD display Icon TrunkingType Special requirements Programming Trunking Frequencies010 Programming ID Scan Lists ManuallyM5-0 4128 1216¡ M5-0 050-2¡E5-0 09-022¡ M5-0 02-120¡1216 To enter a LTR IDReceiving Trunked Systems ID Scan 867.9875 FM List ID Scan ModeID Scan Hold Feature ID Monitor ModeTrunked Search ID Lockout ID Search Hold and Direct Entry ID Hold ModeID4128 867.8375 FMRestoring Locked-out IDs Review ID LockoutLT ID0-02-042 To unlock a single ID, follow these steps Press MENU/BACKReverse Key Setting the Delay Mode for Trunking ModeSetting Priority in Trunking Mode Programming Scan Lists During SearchDeleting a Stored ID Call Motorola/EDACS Moving between Scan List MemoriesMulti-Track Calls in Scan and Hold ModeMulti-Track Operational Details Edacs Tracking Edacs ReceptionSearch An Edacs Trunked systemAFS Partial Entry Feature Special Edacs FeaturesPatch Tracking LTR Tracking LTR ReceptionMotorola Tracking Motorola ReceptionSelecting Preset Fleet Map Fleet Map Programming001 867.8375 FM 1TYPE2 800 2TYPE1 Programming a Hybrid System Programming a Fleet Map001 867.8375 FM 1TYPE2 001 FM Block 0 Size Code50.0 Toggling the Status Bit Control Channel Only ModePage Disconnect Tone Detect Option End Code Remote Interface PC Control ModeTo connect Scanner to PC To program your scannerStart Remote Mode and Change Transfer Speed Clone ModeSpeed 39600 bps 419200 bps PC Control ParameterChanger Cable available at most computer stores To connect the Scanner to ScannerClone Dimmer Additional FeaturesEnter Lock Key LockKey Beep Option Reverse ModeScreen Mask Channel Step SelectionReceiving Mode Selection Frequency and Channel Tuning with the VFO ControlMute On/Off Care and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Appendix Preset Fleet MapsSize Code Type I Programming Information User Defined Fleet MapsSize Code Restrictions Fleet Map Size CodesReverse List UBC3300XLT Flow Charts Scan Option Conventional System Option Dimmer Dimmer Light Dimmer Time Screen Mask Declaration of Conformity Memo UBZZ01315AZ