Uniden UBC3300XLT manual Programming Trunking Frequencies

Page 50

For Type 1 System, you must enter the block and fleet numbers. Please refer to “Programming a Fleet Map” on page 67 for instructions.

STEP 1 is complete.

No.

LCD display

Icon

TrunkingType

Special requirements

1

Type 2 800

M

Motorola Type 2 800 MHz

 

2

Type 1

M

Motorola Type 1

a. Must program a fleet map.

3

Type 2 900

M

Motorola Type 2 900 MHz

 

4

Type 2 UHF

M

Motorola Type 2 UHF

b. Must program base, spacing,

5

Type 2 VHF

M

Motorola Type 2 VHF

frequency and offset channel.

 

6

EDCS WIDE

E

EDACS Wideband 9600 baud

c. Must program frequencies

7

EDCS NARROW

E

EDACS Narrowband 4800 baud

in exact order and location.

 

8

EDCS SCT.

E

EDACS SCAT

 

9

LT

L

LTR

 

STEP 2:

Programming Trunking Frequencies

After you finish selecting the bank and trunk type you want to track, store the frequencies in the channels for your selected bank in your scanner. Remember that you can only store one trunking system in each bank.

Important: If you are programming an EDACS or LTR trunked system, you must enter the frequencies in a specific order. Check the frequency guide included with the scanner for the frequencies in your area. For additional frequencies, check the web sites listed on page 11.

1.Press MENU/BACK.

2.Select 2:SCAN OPTION /

2:TRUNK by rotating the VFO and pressing E.

3.Select the bank number by rotating the VFO and pressing E.

CH/

 

 

FRQ

 

 

HOLD/

 

RSM

MAN

 

SCAN

AIR/STEP

SEARCH

MENU/BACK

 

TRUNK

L/O

REVERSESELECT

.E

4.Select 2:TRUNK CHANNEL and enter the channel number by rotating the VFO and pressing E.

5.Select 1:FREQUENCY and enter a frequency for the trunked system using the keypad and pressing E.

6.Enter the alpha tag and press E. (See page 49).

7You can also change the step size in this menu.(See page 92)

Note: • To clear a mistake while entering the frequency, press . (decimal key) twice, and the display is cleared.

46

Image 50
Contents Page Page Contents Edacs Scat Introduction LTRFront View Icon Display Icon DescriptionUBC3300XLT Shortcuts Then enter the trunk type you want to track. Press E Important Notice What is Trunk Tracking? What is Scanning?What is Searching? TerminologyPage Feature Highlights Page Where to Obtain More Information Information on the InternetIncluded with Your Scanner Package Charging the Battery Pack SetupInstalling the Battery Pack Low Battery IndicatorBeltclip Connecting the Optional Remote CableFlexible Antenna Listening SafelyTurn the Scanner On Setting the SquelchBasic Operation Understanding the Menu System Menu Description and Numeric Keypad Equivalents Set attenuation for all search ranges. See 2SCAN 2SCAN Option 1CONVENTIONAL 6STEPS You can assign a variety of step sizes to the channel 8I-CALLMOTOROLA/EDACS 0EDACS ID Form Edacs 3SYSTEM Option 1DIMMER Select 2DISABLE in this mode Press MENU/BACK Storing Frequencies into Channels in Menu ModeProgramming Duplicate Frequency Alert Deleting a Stored FrequencyEditing a Stored Frequency 010 512.0000 FMPress HOLD/MAN Transfer FrequenciesStoring Text Tags Assigning a Bank Tag to a Bank Press MENU/BACKAssigning the Beep Alert to a Channel Beep Alert855.0000 Programming Tips 001 ScanningStoring Frequencies During Scanning BankRF Attenuation Feature Setting the Delay Mode for FrequencyChannel Lockout Lockout in Hold Mode Press HOLD/MANLockout in Scanning Mode 001 141.5000 FM Uniden Group aPriority Scan Restoring a Locked-out ChannelRestoring All Locked-out Channels 001 512.0000 FM Changing the Priority ChannelPriority Channel Plus Scan Srch 12.5k 1240.0000 FM Range Setting a Search RangeSearching Data Skip Search Hold FeatureStarting Chain Search Srch 12.5k 1240.0000 FM Range 25cm Amateur GrpFrequency Skip Storing Search Frequencies12--56 Auto Storing12.5k Squelch SQ Mode 001 FM Bank001 512.0000 FM Bank 001 512.0000 FM Ctcss 250.3 Bank001 FM DCS Bank 003 512.0000 FM Ctcss Uniden Group aAdditional Menu Options for Searching Press AIR/STEP Air Service SearchAir Service Search Skip Service Search AIR 001 0000.0000 Programming Receiving Trunked SystemsSelecting or Changing Trunking System Type Programming Trunking Frequencies LCD display Icon TrunkingType Special requirementsProgramming ID Scan Lists Manually 010E5-0 09-022¡ M5-0 4128 1216¡M5-0 050-2¡ 1216 02-120¡M5-0 To enter a LTR IDReceiving Trunked Systems ID Scan Mode ID Scan 867.9875 FM ListTrunked Search ID Scan Hold FeatureID Monitor Mode ID4128 ID Search Hold and Direct Entry ID Hold ModeID Lockout 867.8375 FMLT ID0-02-042 Review ID LockoutRestoring Locked-out IDs To unlock a single ID, follow these steps Press MENU/BACKSetting the Delay Mode for Trunking Mode Reverse KeyDeleting a Stored ID Setting Priority in Trunking ModeProgramming Scan Lists During Search Moving between Scan List Memories Call Motorola/EDACSCalls in Scan and Hold Mode Multi-TrackMulti-Track Operational Details Edacs Reception Edacs TrackingAn Edacs Trunked system SearchSpecial Edacs Features AFS Partial Entry FeaturePatch Tracking LTR Reception LTR TrackingMotorola Reception Motorola Tracking001 867.8375 FM 1TYPE2 800 2TYPE1 Selecting Preset Fleet MapFleet Map Programming 001 867.8375 FM 1TYPE2 Programming a Fleet MapProgramming a Hybrid System 001 FM Block 0 Size Code50.0 Control Channel Only Mode Toggling the Status BitPage Disconnect Tone Detect Option End Code To connect Scanner to PC PC Control ModeRemote Interface To program your scannerSpeed 39600 bps 419200 bps Clone ModeStart Remote Mode and Change Transfer Speed PC Control ParameterTo connect the Scanner to Scanner Changer Cable available at most computer storesClone Enter Lock Additional FeaturesDimmer Key LockScreen Mask Reverse ModeKey Beep Option Channel Step SelectionMute On/Off Receiving Mode SelectionFrequency and Channel Tuning with the VFO Control Care and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Preset Fleet Maps AppendixSize Code User Defined Fleet Maps Type I Programming InformationFleet Map Size Codes Size Code RestrictionsReverse List UBC3300XLT Flow Charts Scan Option Conventional System Option Dimmer Dimmer Light Dimmer Time Screen Mask Declaration of Conformity Memo UBZZ01315AZ