Uniden UBC3300XLT manual Channel Lockout, 001 141.5000 FM Uniden Group a, Lockout in Scanning Mode

Page 37

1:CONVENTIONAL by rotating the VFO and pressing

E.

3.Select the channel number of the stored frequency to be delayed by rotating the VFO and pressing E.

4.Select 2:DELAY and press E.

5.Rotate the VFO to select 1:ON or 2:OFF and press E.

6.For Search mode, select 1:SERVICE OPTION /

2:CHAIN SEARCH/3:DELAY by rotating the VFO and pressing E, then set to 1:ON or 2:OFF the same way as the Scan mode setting.

Channel Lockout

You can lockout any channel so it is not checked during normal scanning. You can restore the channel to scanning when you wish.

Lockout in Hold Mode

1.Press HOLD/MAN.

2.Select a channel.

a.Enter the channel number using the keypad.

b.Press HOLD/MAN again.

–––OR –––

Rotate the VFO up or down to change the channel.

3.Press L/O to lockout the channel. L/O appears on the display.

Lockout in Scanning Mode

CH/

 

 

FRQ

 

 

HOLD/

 

RSM

MAN

 

 

SCAN

AIR/STEP

SEARCH

MENU/BACK

 

TRUNK

L/O

REVERSESELECT

.E

C 001

141.5000 FM

UNIDEN Group A

If the scanner keeps stopping on a particular channel due to noise or frequent transmissions, you may want to keep that channel from scanning.

1.Wait until the scanner stops on the channel.

2.Then press L/O.

3.The scanner immediately resumes scanning because the locked out channel is no longer in the scanning sequence.

Lockout Tips

Write down your locked-out channels and

 

put in a convenient place in case you need

 

to restore them.

33

Image 37
Contents Page Page Contents Edacs Scat LTR IntroductionFront View Icon Description Icon DisplayUBC3300XLT Shortcuts Then enter the trunk type you want to track. Press E Important Notice What is Searching? What is Scanning?What is Trunk Tracking? TerminologyPage Feature Highlights Page Information on the Internet Where to Obtain More InformationIncluded with Your Scanner Package Installing the Battery Pack SetupCharging the Battery Pack Low Battery IndicatorFlexible Antenna Connecting the Optional Remote CableBeltclip Listening SafelyBasic Operation Setting the SquelchTurn the Scanner On Understanding the Menu System Menu Description and Numeric Keypad Equivalents Set attenuation for all search ranges. See 2SCAN 2SCAN Option 1CONVENTIONAL 6STEPS You can assign a variety of step sizes to the channel 8I-CALLMOTOROLA/EDACS 0EDACS ID Form Edacs 3SYSTEM Option 1DIMMER Select 2DISABLE in this mode Programming Storing Frequencies into Channels in Menu ModePress MENU/BACK Editing a Stored Frequency Deleting a Stored FrequencyDuplicate Frequency Alert 010 512.0000 FMStoring Text Tags Transfer FrequenciesPress HOLD/MAN Assigning a Bank Tag to a Bank Press MENU/BACK855.0000 Beep AlertAssigning the Beep Alert to a Channel Programming Tips Storing Frequencies During Scanning Scanning001 BankSetting the Delay Mode for Frequency RF Attenuation FeatureLockout in Scanning Mode Lockout in Hold Mode Press HOLD/MANChannel Lockout 001 141.5000 FM Uniden Group aRestoring All Locked-out Channels Restoring a Locked-out ChannelPriority Scan Priority Channel Plus Scan Changing the Priority Channel001 512.0000 FM Searching Setting a Search RangeSrch 12.5k 1240.0000 FM Range Starting Chain Search Search Hold FeatureData Skip Srch 12.5k 1240.0000 FM Range 25cm Amateur GrpStoring Search Frequencies Frequency Skip12.5k Auto Storing12--56 001 FM Bank Squelch SQ Mode001 FM DCS Bank 001 512.0000 FM Ctcss 250.3 Bank001 512.0000 FM Bank 003 512.0000 FM Ctcss Uniden Group aAdditional Menu Options for Searching Air Service Search Skip Air Service SearchPress AIR/STEP Service Search AIR Selecting or Changing Trunking System Type Programming Receiving Trunked Systems001 0000.0000 LCD display Icon TrunkingType Special requirements Programming Trunking Frequencies010 Programming ID Scan Lists ManuallyM5-0 050-2¡ M5-0 4128 1216¡E5-0 09-022¡ M5-0 02-120¡1216 To enter a LTR IDReceiving Trunked Systems ID Scan 867.9875 FM List ID Scan ModeID Monitor Mode ID Scan Hold FeatureTrunked Search ID Lockout ID Search Hold and Direct Entry ID Hold ModeID4128 867.8375 FMRestoring Locked-out IDs Review ID LockoutLT ID0-02-042 To unlock a single ID, follow these steps Press MENU/BACKReverse Key Setting the Delay Mode for Trunking ModeProgramming Scan Lists During Search Setting Priority in Trunking ModeDeleting a Stored ID Call Motorola/EDACS Moving between Scan List MemoriesMulti-Track Calls in Scan and Hold ModeMulti-Track Operational Details Edacs Tracking Edacs ReceptionSearch An Edacs Trunked systemAFS Partial Entry Feature Special Edacs FeaturesPatch Tracking LTR Tracking LTR ReceptionMotorola Tracking Motorola ReceptionFleet Map Programming Selecting Preset Fleet Map001 867.8375 FM 1TYPE2 800 2TYPE1 Programming a Hybrid System Programming a Fleet Map001 867.8375 FM 1TYPE2 001 FM Block 0 Size Code50.0 Toggling the Status Bit Control Channel Only ModePage Disconnect Tone Detect Option End Code Remote Interface PC Control ModeTo connect Scanner to PC To program your scannerStart Remote Mode and Change Transfer Speed Clone ModeSpeed 39600 bps 419200 bps PC Control ParameterChanger Cable available at most computer stores To connect the Scanner to ScannerClone Dimmer Additional FeaturesEnter Lock Key LockKey Beep Option Reverse ModeScreen Mask Channel Step SelectionFrequency and Channel Tuning with the VFO Control Receiving Mode SelectionMute On/Off Care and Maintenance Troubleshooting Problem Suggestion Specifications Glossary of Terms Page Page Appendix Preset Fleet MapsSize Code Type I Programming Information User Defined Fleet MapsSize Code Restrictions Fleet Map Size CodesReverse List UBC3300XLT Flow Charts Scan Option Conventional System Option Dimmer Dimmer Light Dimmer Time Screen Mask Declaration of Conformity Memo UBZZ01315AZ