FLEXNet DC Measurements

The FLEXNet DC can measure and record:

 

 

 

• Volts for one battery bank*

 

 

 

• Amps**

For

each

 

• KiloWatts

 

 

channel

 

 

• kWhrs removed from the batteries

 

 

 

 

 

• kWhrs returned to the batteries

 

 

 

• Amp hours removed from the batteries

 

 

 

• Amp hours returned to the batteries

 

 

 

• Battery bank state-of-charge

 

 

 

• Lifetime kiloamp hours removed from the batteries***

 

 

• Days since charge parameters last met

 

 

 

• Lowest battery state-of-charge reached

 

 

 

• Minimum battery voltage***

For

 

 

• Maximum battery voltage***

 

 

each

 

 

• Maximum amp charged***

 

 

amps

 

• Maximum amp discharged***

 

 

channel

• Maximum kWhrs charged***

 

• Maximum kWhrs discharged***

* Battery volt input: 0-80 VDC in .1 volt resolution

** 2000 amp DC span (+/- 1000 amps DC—net amps are charging, net amps are discharging), .1 amp resolution

*** The user can manually reset these data. At any given time, the values displayed are the most recent since the values were last displayed

11

Image 12
Contents NetTM DC Warranty About OutBack Power SystemsFLEXnet DC User’s Guide 2007 All rights reserved Disclaimer Date and RevisionContact Information JanuaryTable of Contents OutBack Power Systems FLEXnet DC IntroductionSystem Overview Postion wiring block Reading the FLEXnet DCInstalling the FLEXnet DC FLEXNet DC package includesConnect each twisted pair to a shunt Wiring Block Connections Torque ValuesWhite to BAT Black to BAT + Installing the FLEXnet DC Maximum battery voltage FLEXNet DC MeasurementsKiloWatts Maximum amp chargedUser Adjustable Set Points Logged DataData Logging Programming and Using the Mate for FLEXNet DC Operations All unused channels should be set to disabled FLEXNet DC ModesCharge Cycle Typical charge cycleGreen Yellow RED Auto Mode Programming the Auxiliary RelayRelay Logic Invert Logic Hi Set Point SatisfiedMate Screens Press the DC soft key to view the status of the FlexNet DC ReadingsDown Status STATUS/FN Stats Meter Shunt Batt TOP STATUS/DC/SHUNT a Down UP Reset Down UP Reset TOP STATUS/DC/BATT UP TOP Status ADV BAT Shunt PG2 Press the Charge soft key Press the ADV soft key Press the DC soft keyPG1 Charge AUX PG3 ADV/DC/AUX Control ADV/DC/AUX SOC LOW PG2 Reset CLR Main Battery Charge Factor BCF Technical NotesYear Limited Warranty FLEXnet ProductsRevision.2007-08-29 Limited Warranty Registration Outback Power Systems Inc 19009 62nd Ave. NEREV B