Outback Power Systems DC manual Technical Notes, Battery Charge Factor BCF

Page 30

Technical Notes

Battery Charge Factor (BCF)

Some energy is lost both when recharging and discharging a battery. The FLEXnet DC compensates for these losses by discounting the amp-hours charging the battery, meaning it doesn’t count every hour used for recharging as actually recharging. Some of them are lost due to heat and gassing. The FLEXnet DC’s default BCF is 94, which means for every 100 amp hours of charge to the battery, only 94 are shown in the amp hour display for a BCF of 94%. This means 6% of the amp hours is lost.

As the system goes through a few recharging cycles, the range of state-of-charge (SOC) percentages will vary, but should fall into a predictable range. This allows the user to change the BCF if necessary for more efficient recharging. If the SOC displays as full before the battery charge settings are met (either before the time setting or amp hour setting is satisfied), the BCF should be lowered because it’s assuming too many amp hours have been recharging the battery. By lowering the BCF, the FLEXnet DC will read more hours as being unused due to inefficiency.

29

Image 30
Contents NetTM DC Warranty About OutBack Power SystemsFLEXnet DC User’s Guide 2007 All rights reserved Contact Information DisclaimerDate and Revision JanuaryTable of Contents OutBack Power Systems FLEXnet DC IntroductionSystem Overview Postion wiring block Reading the FLEXnet DCInstalling the FLEXnet DC FLEXNet DC package includesConnect each twisted pair to a shunt Wiring Block Connections Torque ValuesWhite to BAT Black to BAT + Installing the FLEXnet DC KiloWatts Maximum battery voltageFLEXNet DC Measurements Maximum amp chargedUser Adjustable Set Points Logged DataData Logging Programming and Using the Mate for FLEXNet DC Operations Charge Cycle All unused channels should be set to disabledFLEXNet DC Modes Typical charge cycleGreen Yellow RED Relay Logic Auto ModeProgramming the Auxiliary Relay Invert Logic Hi Set Point SatisfiedMate Screens Press the DC soft key to view the status of the FlexNet DC ReadingsDown Status STATUS/FN Stats Meter Shunt Batt TOP STATUS/DC/SHUNT a Down UP Reset Down UP Reset TOP STATUS/DC/BATT UP TOP Status ADV BAT Shunt PG2 Press the Charge soft key Press the ADV soft key Press the DC soft keyPG1 Charge AUX PG3 ADV/DC/AUX Control ADV/DC/AUX SOC LOW PG2 Reset CLR Main Battery Charge Factor BCF Technical NotesYear Limited Warranty FLEXnet ProductsRevision.2007-08-29 Limited Warranty Registration Outback Power Systems Inc 19009 62nd Ave. NEREV B