Outback Power Systems manual Introduction, OutBack Power Systems FLEXnet DC

Page 5

Introduction

The OutBack Power Systems FLEXnet DC

The FLEXNet DC collects, monitors and records time-based battery amp, watt and volt data for display on the OutBack MATE series of products, allowing for more accurate set point adjustments and precise battery recharging. Five LEDs on the FLEXnet DC act as a state-of-charge indicator bar for a quick status display.

The FLEXnet DC also offers an auxiliary (AUX) relay that acts like a switch to turn on or off a user-installed light, alarm, or similar low voltage DC device. It can also be set up as a two-wire auto generator starter.

The FLEXNet DC works in conjunction with up to three input current shunts (either a FW-SHUNT250 or FW-SHUNT500, each rated 500A/50mV) also available from OutBack.

Only a single FLEXNet DC is needed for any system using OutBack components.

The FLEXnet DC is not intended to be used with the MATE2M. It is designed to work with the MATE or the MATE2.

NOTE: • One shunt is included as standard equipment with each OutBack FW500-DC and FW1000-AC enclosures.

• The shunt(s) cannot be connected to a positive (+) ground system.

4

Image 5
Contents NetTM DC FLEXnet DC User’s Guide 2007 All rights reserved WarrantyAbout OutBack Power Systems Date and Revision DisclaimerContact Information JanuaryTable of Contents Introduction OutBack Power Systems FLEXnet DCSystem Overview Reading the FLEXnet DC Postion wiring blockFLEXNet DC package includes Installing the FLEXnet DCConnect each twisted pair to a shunt White to BAT Black to BAT + Wiring Block ConnectionsTorque Values Installing the FLEXnet DC FLEXNet DC Measurements Maximum battery voltageKiloWatts Maximum amp chargedData Logging User Adjustable Set PointsLogged Data Programming and Using the Mate for FLEXNet DC Operations FLEXNet DC Modes All unused channels should be set to disabledCharge Cycle Typical charge cycleGreen Yellow RED Programming the Auxiliary Relay Auto ModeRelay Logic Invert Logic Hi Set Point SatisfiedMate Screens Readings Press the DC soft key to view the status of the FlexNet DCDown Status STATUS/FN Stats Meter Shunt Batt TOP STATUS/DC/SHUNT a Down UP Reset Down UP Reset TOP STATUS/DC/BATT UP TOP Status ADV BAT Shunt PG2 Press the ADV soft key Press the DC soft key Press the Charge soft keyPG1 Charge AUX PG3 ADV/DC/AUX Control ADV/DC/AUX SOC LOW PG2 Reset CLR Main Technical Notes Battery Charge Factor BCFFLEXnet Products Year Limited WarrantyRevision.2007-08-29 Outback Power Systems Inc 19009 62nd Ave. NE Limited Warranty RegistrationREV B